The Centrifuge,laboratory, cataloged under National Stock Number 6640-01-510-9634, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. The manufacturer of record is Beckman Coulter Inc Div Us Customer Operations. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Item Name | Centrifuge,laboratory |
| FSC / FSG | 6640 — Laboratory Equipment and Supplies (FSG 66) |
| Manufacturers | Beckman Coulter Inc Div Us Customer Operations (CAGE 6Z677); Fisher Scientific Company L.l.c. (CAGE 22527) |
| Parameter | Value |
|---|---|
| NSN | 6640-01-510-9634 |
| Primary Part Number | SSX2 |
| Item Name | Centrifuge,laboratory |
| FSC / FSG | 6640 / 66 — Laboratory Equipment and Supplies |
| Manufacturer | Beckman Coulter Inc Div Us Customer Operations |
| Status | ACTIVE |
| Universal Medical Device Nomenclature System Code | 18264 |
| Slot Quantity | 4 |
| Voltage in Volts | 100.0 AND 240.0 |
| Place Container Size | 5ML BLOOD TUBES |
| Accessory Components and Quantity | 4-PLACE ROTOR,1; UNIVERSAL POWER SUPPLY,1; REMOVABLE CHAMBER LINER,1; 5ML INSERTS,4; POWER CORD,1 |
| Maximum Speed Rating in RPM | 8500.0 |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| Operation Method | ELECTRIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| SSX2 PRIMARY | Beckman Coulter Inc Div Us Customer Operations (USA) |
| 22-315-792 | Fisher Scientific Company L.l.c. (USA) |
| Reference | Meaning |
|---|---|
| 6550NCM030989 | 5/1 Secondary reference Defense Medical Standardization Board |
| STAT SPIN EXPRESS 2 | 3/9 Design control — primary reference Fisher Scientific Company L.l.c. |
| 03-1247 | 5/1 Secondary reference U.S. Government activity |
NSN 6640-01-510-9634 is a Centrifuge,laboratory, manufactured by Beckman Coulter Inc Div Us Customer Operations, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.
NSN 6640-01-510-9634 has 2 manufacturer part numbers on file: SSX2 (Beckman Coulter Inc Div Us Customer Operations), 22-315-792 (Fisher Scientific Company L.l.c.).
Key specifications for SSX2: Overall Height: 6.000 INCHES NOMINAL IN; Universal Medical Device Nomenclature System Code: 18264; Slot Quantity: 4; Voltage in Volts: 100.0 AND 240.0. 8 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.