The Analytical Column, cataloged under National Stock Number 6640-01-468-7122, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. The manufacturer of record is Dionex Corporation. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6640-01-468-7122 |
| Primary Part Number | 37041 |
| Item Name | Analytical Column |
| FSC / FSG | 6640 / 66 — Laboratory Equipment and Supplies |
| Manufacturer | Dionex Corporation |
| Status | ACTIVE |
| General Characteristics Item Description | IONPAC AS4A ANALYTICAL COLUMN; CARBONATE ELUENT HAS VERY LOW BACKGROUND, YIELDING EXCELLENT SENSITIVITY; LOW MW ALIPHATIC ORGANIC ACIDS AND MONO- AND DIVALENT ANIONS CAN BE SEPARATED IN A SINGLE RUN USING A SODIUM BORATE GRADIENT |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
NSN 6640-01-468-7122 is a Analytical Column, manufactured by Dionex Corporation, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.
NSN 6640-01-468-7122 has 2 manufacturer part numbers on file: 37041 (Dionex Corporation), 037041 (Dionex Corporation).
2 possible matches (shared part number, not a government interchangeability claim): 4730-01-554-6020, 5860-01-678-8856. Verify interchangeability with system specifications before substitution.
Key specifications for 37041: General Characteristics Item Description: IONPAC AS4A ANALYTICAL COLUMN; CARBONATE ELUENT HAS VERY LOW BACKGROUND, YIELDING EXCELLENT SENSITIVITY; LOW MW ALIPHATIC ORGANIC ACIDS AND MONO- AND DIVALENT ANIONS CAN BE SEPARATED IN A SINGLE RUN USING A SODIUM BORATE GRADIENT; Part Name Assigned by Controlling Agency: ANALYTICAL COLUMN IONPAC AS4A CARBONAT FLUENT VERY LOW BACKGROUN. 1 specification is documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.