The Priming Solution,automated Analy, cataloged under National Stock Number 6640-01-347-1092, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. The manufacturer of record is Beckman Coulter Inc Div Us Customer Operations. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6640-01-347-1092 |
| Primary Part Number | 7546915 |
| Item Name | Priming Solution,automated Analy |
| FSC / FSG | 6640 / 66 — Laboratory Equipment and Supplies |
| Manufacturer | Beckman Coulter Inc Div Us Customer Operations |
| Status | ACTIVE |
| General Characteristics Item Description | 16 ML BOTTLE; PREPARES THE SAMPLE LINE BEFORE ASPIRATING COULTER'S LATRON CONTROL IN ORDER TO ENSURE A BACKGROUND FREE,ELECTROSTATIC FREE PATHWAY FOR THE CONTROL; USED WITH COULTER'S STKS,MAXM AND VCS CLINICAL HEMATOLOGY INSTRUMENTS; UNIT QTY: 5 PER PKG; THIS ITEM IS USUALLY SHIPPED WITH 1 YEAR SHELF LIFE, EXPIRES 30 DAYS AFTER OPENING; LATRON PRIMER PREPARES THE TUBING AND INSTRUMENT COMPONENTS FOR THE LATRON CONTROL FOR COULTER HMX HEMATOLOGY ANALYZER; REFRIGERATION IS REQUIRED AT 2-8 DEG.C |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Hazardous per DLA record (HMIC Y) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 105096 | Analis (BEL) |
| 7546915 PRIMARY | Beckman Coulter Inc Div Us Customer Operations (USA) |
| Reference | Meaning |
|---|---|
| LATRON PRIMER | 5/1 Secondary reference Beckman Coulter Inc Div Us Customer Operations |
| 91-7-23-63 | 5/1 Secondary reference Air Force Medical Logistics Office |
| F91G316 | 5/1 Secondary reference Air Force Medical Logistics Office |
| 7546915 | 5/9 Secondary reference U.S. Government activity |
| 06-0106 | 5/1 Secondary reference U.S. Government activity |
| 273-857 | 5/9 Secondary reference Curtin Matheson Scientific Inc |
NSN 6640-01-347-1092 is a Priming Solution,automated Analy, manufactured by Beckman Coulter Inc Div Us Customer Operations, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.
NSN 6640-01-347-1092 has 2 manufacturer part numbers on file: 105096 (Analis), 7546915 (Beckman Coulter Inc Div Us Customer Operations).
2 possible matches (shared part number, not a government interchangeability claim): 4310-01-420-7941, 3110-01-548-1363. Verify interchangeability with system specifications before substitution.
Key specifications for 7546915: General Characteristics Item Description: 16 ML BOTTLE; PREPARES THE SAMPLE LINE BEFORE ASPIRATING COULTER'S LATRON CONTROL IN ORDER TO ENSURE A BACKGROUND FREE,ELECTROSTATIC FREE PATHWAY FOR THE CONTROL; USED WITH COULTER'S STKS,MAXM AND VCS CLINICAL HEMATOLOGY INSTRUMENTS; UNIT QTY: 5 PER PKG; THIS ITEM IS USUALLY SHIPPED WITH 1 YEAR SHELF LIFE, EXPIRES 30 DAYS AFTER OPENING; LATRON PRIMER PREPARES THE TUBING AND INSTRUMENT COMPONENTS FOR THE LATRON CONTROL FOR COULTER HMX HEMATOLOGY ANALYZER; REFRIGERATION IS REQUIRED AT 2-8 DEG.C; Part Name Assigned by Controlling Agency: PRIMING SOLUTION AUTOMATED ANALYSIS 16 ML BOTTLE 5'S. 1 specification is documented in the U.S. Government catalog.
Hazardous per DLA record (HMIC Y). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.