The Tube,serum Filtering, cataloged under National Stock Number 6640-01-324-3188, is classified within Federal Supply Class 6640 (No Item Name Available) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Porex Technologies Corp. Government technical data includes 3 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 6 commercial cross-references from 6 manufacturers, enabling identification through both NSN and commercial part number lookups. 4 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6640-01-324-3188 |
| Primary Part Number | IB413 |
| Item Name | Tube,serum Filtering |
| FSC / FSG | 6640 / 66 — No Item Name Available |
| Manufacturer | Porex Technologies Corp |
| Status | ACTIVE |
| Features Provided | DISPOSABLE |
| Top Inside Diameter | 13.0 MILLIMETERS NOMINAL MM |
| Material | PLASTIC |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| P5189-4 | Cardinal Health 200, Llc (USA) |
| 90-4-9-9 | Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa (USA) |
| P5189-4 | Baxter Healthcare Corp Baxter Scientific Products Div Government Sales (USA) |
| A90C044 | Air Force Medical Logistics Office (USA) |
| IB413 PRIMARY | Porex Technologies Corp (USA) |
| 148-049 | Curtin Matheson Scientific Inc (USA) |
NSN 6640-01-324-3188 is a Tube,serum Filtering, manufactured by Porex Technologies Corp, classified under FSC 6640 (No Item Name Available). Status: active.
NSN 6640-01-324-3188 has 6 cross-referenced part numbers: P5189-4 (Cardinal Health 200, Llc), 90-4-9-9 (Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa), P5189-4 (Baxter Healthcare Corp Baxter Scientific Products Div Government Sales), A90C044 (Air Force Medical Logistics Office), IB413 (Porex Technologies Corp) and 1 more.
There are 4 known substitutes for 6640-01-324-3188: 5905-00-105-7764, 2925-00-446-8904, 5962-01-090-1936 and 1 more. Verify interchangeability with system specifications before substitution.
Key specifications for IB413: Part Name Assigned by Controlling Agency: TUBE SERUM FILTERING PLASTIC DISPOSABLE 4IN LG 13MM ID 100S MM; Special Features: FILTER FIBRIM FROM SERUM PORTION OF CENTRIFUGE BLOOD SAMPLE AND THE STORAGE W/FILTERED SERUM FOR UP TO 7 DAYS W/CHEMISTRY METHODOLOGY AND 4 DAYS W/COAGULATION METHODOLOGY W/O THE DANGER OF IONIC CONTAMINATION; Features Provided: DISPOSABLE; Top Inside Diameter: 13.0 MILLIMETERS NOMINAL MM. 6 total characteristics are documented in the Federal Logistics Information System.