The Oven,laboratory, cataloged under National Stock Number 6640-01-312-2032, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6640-01-312-2032 |
| Item Name | Oven,laboratory |
| FSC / FSG | 6640 / 66 — Laboratory Equipment and Supplies |
| Status | ACTIVE |
| Shelf Quantity | 1 |
| Inside Width | 11.000 INCHES NOMINAL IN |
| Current Type | AC |
| Control Type | THERMOSTAT |
| Inside Depth | 10.000 INCHES NOMINAL IN |
| Insulated Cabinet | PROVIDED |
| Material Characteristic | SOLID |
| Outside Depth | 12.300 INCHES NOMINAL IN |
| Heat Source for Which Designed | INTEGRAL |
| Circulation Method | FORCED AIR OR GRAVITY |
| Outside Width | 13.400 INCHES NOMINAL IN |
| Outer Door Quantity | 1 |
| Operating Temp Range | +40.0 TO 220.0 CELSIUS DEGC |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| Material | STEEL CABINET OUTER WALL |
| Material | STEEL SHELF |
| Heating Method | ELECTRICAL |
| Inside Height | 10.000 INCHES NOMINAL IN |
| Voltage Rating | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
| Water Jacket | NOT PROVIDED |
| Shelf Adjustability | ADJUSTABLE |
| Outside Height | 17.600 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 13-245-506G | 3/9 Design control — primary reference Fisher Scientific Company L.l.c. |
NSN 6640-01-312-2032 is a Oven,laboratory, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.
Key specifications for 6640-01-312-2032: Shelf Quantity: 1; Inside Width: 11.000 INCHES NOMINAL IN; Current Type: AC; Control Type: THERMOSTAT. 22 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.