PartsTable TECHNICAL DATA SHEET
NSN 6640-01-266-4566Government record, cited

Calibration Kit, Pipet Volumetric6640-01-266-4566

NSN 6640-01-266-4566 · NIIN 012664566 · Part number 9082
Medical Laboratory Automation Inc · FSC 6640 — Laboratory Equipment and Supplies · FSG 66 — Instruments and Laboratory Equipment · CAGE 51555
Government record, cited
NSN 6640-01-266-4566 — this item is cataloged by the U.S. Government under National Stock Number 6640-01-266-4566. Manufacturer of record part number: 9082.
Also searched as  6640-01-266-4566 · 6640012664566 · NIIN 012664566 · 01-266-4566 · FSC 6640 Laboratory Equipment and Supplies · CAGE 51555 · 9082 · P5064-3 · 87-9-18-25 · P5064-3
Nearby stock numbers  ·
Features
  • Calibration Kit,pipet Volumetric — FSC 6640
  • Component Quantity: 238
  • Unit Package Quantity: 1
  • Nonsupply Items and Quantities: SEALED CUVETTES CONTAINING SET OF STANDARD CONCENTRATIONS 4; VIALS OF REAGENTS 10; 12MM CALIBRATION CUVETTES 100; GRAPH PAPER 1; STRAIGHT EDGE RULER 1; QC RECORD SHEET 1; LABELS 120; INSTRUCTION MANUAL 1 MM
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Medical Laboratory Automation Inc
Identification
  • NSN: 6640-01-266-4566
  • NIIN: 012664566
  • FSC: 6640 — Laboratory Equipment and Supplies
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 9082
  • Manufacturer: Medical Laboratory Automation Inc
General Description

The Calibration Kit,pipet Volumetric, cataloged under National Stock Number 6640-01-266-4566, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. The manufacturer of record is Medical Laboratory Automation Inc. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6640-01-266-4566
Primary Part Number9082
Item NameCalibration Kit,pipet Volumetric
FSC / FSG6640 / 66 — Laboratory Equipment and Supplies
ManufacturerMedical Laboratory Automation Inc
StatusACTIVE
Component Quantity238
Unit Package Quantity1
Nonsupply Items and QuantitiesSEALED CUVETTES CONTAINING SET OF STANDARD CONCENTRATIONS 4; VIALS OF REAGENTS 10; 12MM CALIBRATION CUVETTES 100; GRAPH PAPER 1; STRAIGHT EDGE RULER 1; QC RECORD SHEET 1; LABELS 120; INSTRUCTION MANUAL 1 MM
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5330-01-486-94749082 POSSIBLE MATCH
RETAINER,SEAL
Possible match (shared part number)Cunico Corporation
7510-01-545-7975 POSSIBLE MATCH
TAPE,PRESSURE SENSITIVE ADHESIVE
Possible match (shared part number)
6505-01-616-58249082 POSSIBLE MATCH
CHLORHEXIDINE GLUCONATE ORAL RIN
Possible match (shared part number)Haws Corporation
Cross-Reference Index
Part NumberManufacturer
9082 PRIMARY Medical Laboratory Automation Inc (USA)
P5064-3 Cardinal Health 200, Llc (USA)
Reference documents
ReferenceMeaning
P5064-3 5/9 Secondary reference
Baxter Healthcare Corp Baxter Scientific Products Div Government Sales
87-9-18-25 5/1 Secondary reference
Air Force Medical Logistics Office
Related Parts
5330-01-486-9474POSSIBLE MATCH
RETAINER,SEAL
9082
7510-01-545-7975POSSIBLE MATCH
TAPE,PRESSURE SENSITIVE ADHESIVE
6505-01-616-5824POSSIBLE MATCH
CHLORHEXIDINE GLUCONATE ORAL RIN
9082

Frequently Asked Questions

What is NSN 6640-01-266-4566?

NSN 6640-01-266-4566 is a Calibration Kit,pipet Volumetric, manufactured by Medical Laboratory Automation Inc, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.

What part numbers are listed for NSN 6640-01-266-4566?

NSN 6640-01-266-4566 has 2 manufacturer part numbers on file: 9082 (Medical Laboratory Automation Inc), P5064-3 (Cardinal Health 200, Llc).

What NSN replaces 6640-01-266-4566?

3 possible matches (shared part number, not a government interchangeability claim): 5330-01-486-9474, 7510-01-545-7975, 6505-01-616-5824. Verify interchangeability with system specifications before substitution.

What are the specifications of 9082?

Key specifications for 9082: Component Quantity: 238; Unit Package Quantity: 1; Nonsupply Items and Quantities: SEALED CUVETTES CONTAINING SET OF STANDARD CONCENTRATIONS 4; VIALS OF REAGENTS 10; 12MM CALIBRATION CUVETTES 100; GRAPH PAPER 1; STRAIGHT EDGE RULER 1; QC RECORD SHEET 1; LABELS 120; INSTRUCTION MANUAL 1 MM; Special Features: DESIGNED TO TEST THE DELIVERED VOLUME OF LABORATORY PIPET WITHIN RANGE OF 10 TO 100 MICROLITERS; NO. OF TESTS 100; USED WITH DISCRETE SAMPLE SPECTROPHOTOMETERS. 3 specifications are documented in the U.S. Government catalog.

Is NSN 6640-01-266-4566 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.