The Furnace Control,console, cataloged under National Stock Number 6640-01-067-2759, is classified within Federal Supply Class 6640 (Laboratory Equipment and Supplies) of the Instruments and Laboratory Equipment group. Government technical data includes 1 specification, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6640-01-067-2759 |
| Item Name | Furnace Control,console |
| FSC / FSG | 6640 / 66 — Laboratory Equipment and Supplies |
| Status | ACTIVE |
| General Characteristics Item Description | 3-ZONE POWER SUPPLY,3 DIGITAL TEMP CONTROLLERS,ON/OFF CIRCUIT BREAKER,DIGITAL DIAL CALIBRATED FOR PLATINEL II THERMOCOUPLE,TEMP RANGE 200-1200 DEG C; ADJUSTABLE PROPORTIONAL BAND,4-40 DEG C; AUTOMATIC RESET,1-10 MIN/RESET; MAX FURNACE LOAD 70 A; 120/240 VAC,SINGLE PHASE,50/60 HZ; 31.5 IN. W,9 IN. H,19.5 IN. D VAC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 59744-A | 3/9 Design control — primary reference General Signal Corp Lindberg Unit |
| 10-467-210 | 5/9 Secondary reference Fisher Scientific Company L.l.c. |
| F8453 | 5/9 Secondary reference Baxter Healthcare Corp Baxter Scientific Products Div Government Sales |
| 15925-10 | 5/9 Secondary reference Curtin Matheson Scientific Inc |
NSN 6640-01-067-2759 is a Furnace Control,console, classified under FSC 6640, Laboratory Equipment and Supplies. Status: active.
Key specifications for 6640-01-067-2759: General Characteristics Item Description: 3-ZONE POWER SUPPLY,3 DIGITAL TEMP CONTROLLERS,ON/OFF CIRCUIT BREAKER,DIGITAL DIAL CALIBRATED FOR PLATINEL II THERMOCOUPLE,TEMP RANGE 200-1200 DEG C; ADJUSTABLE PROPORTIONAL BAND,4-40 DEG C; AUTOMATIC RESET,1-10 MIN/RESET; MAX FURNACE LOAD 70 A; 120/240 VAC,SINGLE PHASE,50/60 HZ; 31.5 IN. W,9 IN. H,19.5 IN. D VAC. 1 specification is documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.