The X-Ray Apparatus,radiographic,ind, cataloged under National Stock Number 6635-01-344-6403, is classified within Federal Supply Class 6635 (Physical Properties Testing and Inspection) of the Instruments and Laboratory Equipment group. The manufacturer of record is Lorad Corporation Dba Lorad Medical Systems Div Lorad Industrial Imaging. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6635-01-344-6403 |
| Primary Part Number | 3-000A-0735 |
| Item Name | X-Ray Apparatus,radiographic,ind |
| FSC / FSG | 6635 / 66 — Physical Properties Testing and Inspection |
| Manufacturer | Lorad Corporation Dba Lorad Medical Systems Div Lorad Industrial Imaging |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Hazardous per DLA record (HMIC Y) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 3-000A-0735 PRIMARY | Lorad Corporation Dba Lorad Medical Systems Div Lorad Industrial Imaging (USA) |
NSN 6635-01-344-6403 is a X-Ray Apparatus,radiographic,ind, manufactured by Lorad Corporation Dba Lorad Medical Systems Div Lorad Industrial Imaging, classified under FSC 6635, Physical Properties Testing and Inspection. Status: active.
NSN 6635-01-344-6403 has 1 manufacturer part number on file: 3-000A-0735 (Lorad Corporation Dba Lorad Medical Systems Div Lorad Industrial Imaging).
Key specifications for 3-000A-0735: Special Features: X-RAY TUBE HEAD IS GAS INSULATED WITH HIGH VOLTAGE GENERATED IN HEAD OUTPUT 150/160 KV CONTINUOUSLY VARIABLE.CONTROLS ARE KV CONTROL ADJUST,X-RAY TUBE CURRENT,MA CONTROL,LINE POWER CIRCUIT BREAKER,SAFETY KEY SWITCH & TIMER CONTROL;KEY SWITCH ENABLES/DISABLES POWER SUPPLY TO CONTROL UNIT & RESTRICTS OPERATION TO AUTHORIZED PERSONNEL;TIMER CONTROLS-RESET SWITCH,TIMER PRESET SWITCH.TIMER SETTING FROM 0.1 TO 99.9 MIN.IN 0.1 MIN.STEPS;INDICATORS/METERS-POWER ON LIGHT GLOWS GREEN WHEN ON,X-RAY ON LIGHT GLOWS RED WHEN X-RAY SWITCH CLOSED.KV METER INDICATES VOLTAGE APPLIED TO TUBE HEAD.MA METER INDICATES TUBE CURRENT;CLOSED SELF-CONTAINED COOLING UNIT PROVIDES COOLING UP TO 50 FEET ABOVE THE UNIT & PROVIDED WITH TWIN 50 FEET HOSES WITH QUICK DISCONNECTS CONNECTIONS FT. 0 specifications are documented in the U.S. Government catalog.
Hazardous per DLA record (HMIC Y). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.