PartsTable TECHNICAL DATA SHEET
NSN 6635-00-960-5061Government record, cited

Leak Detector, Ultrasonic6635-00-960-5061

NSN 6635-00-960-5061 · NIIN 009605061
FSC 6635 — Physical Properties Testing and Inspection · FSG 66 — Instruments and Laboratory Equipment
Government record, cited
Also searched as  6635-00-960-5061 · 6635009605061 · NIIN 009605061 · 00-960-5061 · FSC 6635 Physical Properties Testing and Inspection
Nearby stock numbers  ·
Features
  • Leak Detector,ultrasonic — FSC 6635
  • Relationship to Similar Equipment: WHEN EXHAUSTED USE 6635-00-242-1498
  • General Characteristics Item Description: 3.875 IN.W,7.000 IN. H,1.125 IN.THK,5.0 LBS,POWER SOURCE-THREE STANDARD AA PENLIGHT CELLS,SENSITIVITY-0.1 SCCS OR 0.0002 SCFM LBS
  • Reference Data and Literature: ENGINEERING TEST REPORT NO. 6114-7947-MU-000,AF 04(694-3),8JANUARY 1963; THE RALPH M. PARSONS CO AGE LIST (FIGURE A),REPORT NO. 1872(60-50),ITEM NO. 4996; DELCON CORP,COMMERCIAL DATA; DELCON CORP PART NO. 80019-E1,MODEL 112
  • Functional Classification: AA-5.3
  • Entry Date: 70-04-01
  • Functional Description: DESIGNED FOR DETECTING SMALL GASEOUS LEAKS FROM A DISTANCE OF SEVERAL FEET WITHOUT APPLYING THE DETECTOR TO THE ITEM UNDER TEST. THE UNIT DETECTS ULTRASONIC SOUND PRESSURES CREATED BY THE FLOW OF GAS MOLECULES AS THEY ESCAPE THROUGH HOLES OR FLAWS IN PRESSURIZED EQUIPMENT AND GIVES THE OPERATOR BOTH AN AURAL AND VISUAL INDICATION. THE DETECTOR IS USED FOR CHECKING TITAN II COMPONENTS UNDER TEST,MAINTENANCE OR OVERHAUL. APPLICABLE TO WS107C (LGM-25C).
Identification
  • NSN: 6635-00-960-5061
  • NIIN: 009605061
  • FSC: 6635 — Physical Properties Testing and Inspection
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Leak Detector,ultrasonic, cataloged under National Stock Number 6635-00-960-5061, is classified within Federal Supply Class 6635 (Physical Properties Testing and Inspection) of the Instruments and Laboratory Equipment group. Government technical data includes 6 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6635-00-960-5061
Item NameLeak Detector,ultrasonic
FSC / FSG6635 / 66 — Physical Properties Testing and Inspection
StatusACTIVE
Relationship to Similar EquipmentWHEN EXHAUSTED USE 6635-00-242-1498
General Characteristics Item Description3.875 IN.W,7.000 IN. H,1.125 IN.THK,5.0 LBS,POWER SOURCE-THREE STANDARD AA PENLIGHT CELLS,SENSITIVITY-0.1 SCCS OR 0.0002 SCFM LBS
Reference Data and LiteratureENGINEERING TEST REPORT NO. 6114-7947-MU-000,AF 04(694-3),8JANUARY 1963; THE RALPH M. PARSONS CO AGE LIST (FIGURE A),REPORT NO. 1872(60-50),ITEM NO. 4996; DELCON CORP,COMMERCIAL DATA; DELCON CORP PART NO. 80019-E1,MODEL 112
Functional ClassificationAA-5.3
Entry Date70-04-01
Functional DescriptionDESIGNED FOR DETECTING SMALL GASEOUS LEAKS FROM A DISTANCE OF SEVERAL FEET WITHOUT APPLYING THE DETECTOR TO THE ITEM UNDER TEST. THE UNIT DETECTS ULTRASONIC SOUND PRESSURES CREATED BY THE FLOW OF GAS MOLECULES AS THEY ESCAPE THROUGH HOLES OR FLAWS IN PRESSURIZED EQUIPMENT AND GIVES THE OPERATOR BOTH AN AURAL AND VISUAL INDICATION. THE DETECTOR IS USED FOR CHECKING TITAN II COMPONENTS UNDER TEST,MAINTENANCE OR OVERHAUL. APPLICABLE TO WS107C (LGM-25C).
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
80019E1 3/9 Design control — primary reference
Agilent Technologies Inc. Div Network Systems Test Site
No interchangeability data on file.
Other items in FSC 6635 — Physical Properties Testing and Inspection
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6635-00-000-0133
X-RAY APPARATUS,RADIOGRAPHIC,IND
6635-00-001-1523
FILM,RADIOGRAPHIC
6635-00-001-2317
6635-00-001-2317 · Item name not on file
6635-00-001-2318
6635-00-001-2318 · Item name not on file
6635-00-003-0281
TESTER,TORQUE WRENCH
6635-00-003-0282
CALIBRATOR,TORQUE
6635-00-003-0284
CALIBRATOR,TORQUE
6635-00-003-1193
6635-00-003-1193 · Item name not on file

Frequently Asked Questions

What is NSN 6635-00-960-5061?

NSN 6635-00-960-5061 is a Leak Detector,ultrasonic, classified under FSC 6635, Physical Properties Testing and Inspection. Status: active.

What are the specifications of 6635-00-960-5061?

Key specifications for 6635-00-960-5061: Relationship to Similar Equipment: WHEN EXHAUSTED USE 6635-00-242-1498; General Characteristics Item Description: 3.875 IN.W,7.000 IN. H,1.125 IN.THK,5.0 LBS,POWER SOURCE-THREE STANDARD AA PENLIGHT CELLS,SENSITIVITY-0.1 SCCS OR 0.0002 SCFM LBS; Reference Data and Literature: ENGINEERING TEST REPORT NO. 6114-7947-MU-000,AF 04(694-3),8JANUARY 1963; THE RALPH M. PARSONS CO AGE LIST (FIGURE A),REPORT NO. 1872(60-50),ITEM NO. 4996; DELCON CORP,COMMERCIAL DATA; DELCON CORP PART NO. 80019-E1,MODEL 112; Functional Classification: AA-5.3. 6 specifications are documented in the U.S. Government catalog.

Is NSN 6635-00-960-5061 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com