The Analyzer,clinical Chemistry, cataloged under National Stock Number 6632-01-734-9169, is classified within Federal Supply Class 6632 (Medical Laboratory Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6632-01-734-9169 |
| Primary Part Number | A47326 |
| Item Name | Analyzer,clinical Chemistry |
| FSC / FSG | 6632 / 66 — Medical Laboratory Analysis Instruments |
| Manufacturer | Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| A47326 PRIMARY | Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division (USA) |
| Reference | Meaning |
|---|---|
| 1703158 | 5/1 Secondary reference U.S. Government activity |
| QUANTSTUDIO 5 DX REAL-TIME PCR | 5/1 Secondary reference Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division |
| 6632NCM252012 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6632-01-734-9169 is a Analyzer,clinical Chemistry, manufactured by Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division, classified under FSC 6632, Medical Laboratory Analysis Instruments. Status: active.
NSN 6632-01-734-9169 has 1 manufacturer part number on file: A47326 (Thermo Fisher Scientific (asheville) Llc Div Laboratory Products Division).
Key specifications for A47326: Special Features: THE APPLIED BIOSYSTEMS QUANTSTUDIO 5 DX REAL-TIME PCR SYSTEM IS AN IN VITRO DIAGNOSTIC (IVD) QUANTITATIVE PCR SYSTEM. THIS SYSTEM IS BOTH US-IVD AND AND CE-IVD, IVDR COMPLIANT. REACTION VOLUME 96-WELL, 0.2 ML BLOCK: 10 100 L. EXCITATION SOURCE: BRIGHT-WHITE LED. OPTICAL DETECTION: 6 DECOUPLED FILTERS, CMOS CAMERA. TEMPERATURE RANGE: 4 99.9 C. MAXIMUM BLOCK RAMP RATE 6.5 C/SEC. AVERAGE SAMPLE RAMP RATE 3.66 C/SEC. TEMPERATURE UNIFORMITY 0.5 C. TEMPERATURE ACCURACY 0.25 C. HEATING AND COOLING METHOD PELTIER. INDEPENDENT TEMPERATURE ZONES 6 VERIFLEX ZONES (5 C ZONE TO ZONE). CHEMISTRIES BOTH FAST AND STANDARD. RUN TIMES <30 MIN (FAST MODE). VALIDATED REACTION VOLUMES 10 100 L. FACTORY-CALIBRATED DYES FAM, SYBR, VIC, ABY, NED, TAMRA, JUN, ROX, MUSTANG PURPLE, AND CY 5 DYES. MULTIPLEX 5-PLEX WITH 1 PASSIVE REFERENCE; 6-PLEX WITH NO PASSIVE REFERENCE. DIMENSIONS: 40 X 27 X 50 CM. WEIGHT: 27KG. FORMAT: 96-WELL, 0.2 ML. 100-240VAC.50/60 HZ. 10 AMPS. 960 WATTS. VAC; Part Name Assigned by Controlling Agency: QUANTSTUDIO 5 DX REAL-TIME PCR SYSTEM, LAPTOP. 0 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.