The Analyzer Module,clinical Chemist, cataloged under National Stock Number 6632-01-733-5396, is classified within Federal Supply Class 6632 (Medical Laboratory Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Ysi Inc. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6632-01-733-5396 |
| Primary Part Number | 2950D-4 |
| Item Name | Analyzer Module,clinical Chemist |
| FSC / FSG | 6632 / 66 — Medical Laboratory Analysis Instruments |
| Manufacturer | Ysi Inc |
| Status | ACTIVE |
| Current Type | AC |
| Test Sample/specimen Type | GLUCOSE;LACTATE,GLUTAMATE,GLUTAMINE,AMMONIUM, POTASSIUM,XYLOSE,ETHANOL,METHANOL,SUCROSE,GALACTOSE, CHOLINE,GLYCEROL,HYDROGEN PEROXIDE |
| Voltage in Volts | 220.0 AND 240.0 |
| Features Provided | BATCH PROCESSING AND DIGITAL DISPLAY SCREEN AND INTEGRAL AUTOSAMPLING SYSTEM AND EXTERNAL PRINTER AND RS232 PORT AND SELF-CALIBRATION AND STAT PROCESSING |
| Height | 400.0 MILLIMETERS MM |
| Depth | 521.0 MILLIMETERS MM |
| Width | 356.0 MILLIMETERS MM |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 2950D-4 PRIMARY | Ysi Inc (USA) |
NSN 6632-01-733-5396 is a Analyzer Module,clinical Chemist, manufactured by Ysi Inc, classified under FSC 6632, Medical Laboratory Analysis Instruments. Status: active.
NSN 6632-01-733-5396 has 1 manufacturer part number on file: 2950D-4 (Ysi Inc).
Key specifications for 2950D-4: Current Type: AC; Test Sample/specimen Type: GLUCOSE;LACTATE,GLUTAMATE,GLUTAMINE,AMMONIUM, POTASSIUM,XYLOSE,ETHANOL,METHANOL,SUCROSE,GALACTOSE, CHOLINE,GLYCEROL,HYDROGEN PEROXIDE; Voltage in Volts: 220.0 AND 240.0; Features Provided: BATCH PROCESSING AND DIGITAL DISPLAY SCREEN AND INTEGRAL AUTOSAMPLING SYSTEM AND EXTERNAL PRINTER AND RS232 PORT AND SELF-CALIBRATION AND STAT PROCESSING. 8 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.