The Analyzer Module,clinical Chemist, cataloged under National Stock Number 6632-01-707-3393, is classified within Federal Supply Class 6632 (Medical Laboratory Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Hemosonics, Llc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6632-01-707-3393 |
| Primary Part Number | KT-0022 |
| Item Name | Analyzer Module,clinical Chemist |
| FSC / FSG | 6632 / 66 — Medical Laboratory Analysis Instruments |
| Manufacturer | Hemosonics, Llc |
| Status | ACTIVE |
| Test Type for Which Designed | WHOLE BLOOD HEMOSTASIS/POINT-OF-CARE VISCOELASTIC TESTING |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
NSN 6632-01-707-3393 is a Analyzer Module,clinical Chemist, manufactured by Hemosonics, Llc, classified under FSC 6632, Medical Laboratory Analysis Instruments. Status: active.
NSN 6632-01-707-3393 has 2 manufacturer part numbers on file: KT-0022 (Hemosonics, Llc), KT-0022 (Diagnostica Stago).
Key specifications for KT-0022: Special Features: PROVIDES SEMI-QUANTITATIVE INDICATIONS OF THE COAGULATION AND CLOT LYSIS STATE OF A 3.2 PERCENT CITRATED VENOUS WHOLE BLOOD SAMPLE USING THE HEMOSTASIS ANALYZER. INTENDED FOR IN VITRO DIAGNOSTIC USE BY TRAINED PROFESSIONALS AT THE POINT-OF-CARE AND IN CLINICAL LABORATORIES TO EVALUATE THE VISCOELASTIC PROPERTIES OF WHOLE BLOOD BY MEANS OF THE FOLLOWING FUNCTIONAL PARAMETERS: CLOT TIME (CT), CLOT STIFFNESS (CS), FIBRINOGEN CONTRIBUTION TO CLOT STIFFNESS (FCS), PLATELET CONTRIBUTION TO CLOT STIFFNESS (PCS), AND CLOT STABILITY TO LYSIS (CSL). RESULTS IN 15 MINUTES OR LESS. COMPLETE RESULTS IN 25-60 MINUTES. KIT OF 10.; Part Name Assigned by Controlling Agency: MULTI-CHANNEL CARTRIDGE - WHOLE BLOOD HEMOSTASIS ANALYZER; End Item Identification: 6630-01-703-5661 - HS-001 HEMOSTASIS ANALYZER; Test Type for Which Designed: WHOLE BLOOD HEMOSTASIS/POINT-OF-CARE VISCOELASTIC TESTING. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.