PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

700XRAnalyzer,clinical Chemistry

Johnson & Johnson Health Care Systems Inc. · NSN 6632-01-293-0807 · FSC 6632 · Analyzer,clinical Chemistry
Verified by PartsTable
NSN 6632-01-293-0807 — this item is cataloged by the U.S. Government under National Stock Number 6632-01-293-0807. Primary manufacturer part number: 700XR.
Features
  • Analyzer,clinical Chemistry — FSC 6632
  • 5 verified cross-references
  • Primary manufacturer: Johnson & Johnson Health Care Systems Inc.
Applications
  • Industrial maintenance and repair
  • Government and military logistics
  • Equipment overhaul and refurbishment
General Description

The Analyzer,clinical Chemistry, cataloged under National Stock Number 6632-01-293-0807, is classified within Federal Supply Class 6632 (Analyzer,clinical Chemistry) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Johnson & Johnson Health Care Systems Inc.. This item has 5 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 4 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6632-01-293-0807
Primary Part Number700XR
Item NameAnalyzer,clinical Chemistry
FSC / FSG6632 / 66 — Analyzer,clinical Chemistry
ManufacturerJohnson & Johnson Health Care Systems Inc.
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 4
6632-01-276-94618247355 INTERCHANGEABLE
Analyzer Module,clinical Chemist
Johnson & Johnson Health Care Systems Inc.
6632-01-276-9462 INTERCHANGEABLE
Analyzer Module,clinical Chemist
6632-01-277-6342 INTERCHANGEABLE
Analyzer,clinical Chemistry
6550-01-339-69078262487 INTERCHANGEABLE
Blood Serum Diluent
Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc
Cross-Reference Index
Part NumberManufacturer
EKTACHEM Eastman Kodak Co (USA)
88-12-30-59 Naval Medical Material Support Command Detachment (USA)
6630-0530-0000 Defense Supply Center Richmond Industrial Plant Equipment /dla/ (USA)
700XR PRIMARY Johnson & Johnson Health Care Systems Inc. (USA)
700XR Eastman Kodak Co (USA)
Related Parts
6632-01-276-9461INTERCHANGEABLE
ANALYZER MODULE,CLINICAL CHEMIST
8247355
6632-01-276-9462INTERCHANGEABLE
ANALYZER MODULE,CLINICAL CHEMIST
6632-01-277-6342INTERCHANGEABLE
ANALYZER,CLINICAL CHEMISTRY
6550-01-339-6907INTERCHANGEABLE
BLOOD SERUM DILUENT
8262487

Frequently Asked Questions

What is NSN 6632-01-293-0807?

NSN 6632-01-293-0807 is a Analyzer,clinical Chemistry, manufactured by Johnson & Johnson Health Care Systems Inc., classified under FSC 6632 (Analyzer,clinical Chemistry). Status: active.

What are the part numbers for NSN 6632-01-293-0807?

NSN 6632-01-293-0807 has 5 cross-referenced part numbers: EKTACHEM (Eastman Kodak Co), 88-12-30-59 (Naval Medical Material Support Command Detachment), 6630-0530-0000 (Defense Supply Center Richmond Industrial Plant Equipment /dla/), 700XR (Johnson & Johnson Health Care Systems Inc.), 700XR (Eastman Kodak Co).

What NSN replaces 6632-01-293-0807?

There are 4 known substitutes for 6632-01-293-0807: 6632-01-276-9461, 6632-01-276-9462, 6632-01-277-6342 and 1 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 700XR?

Key specifications for 700XR: Special Features: PROGRAMABLE TO PERFORM ONLY TEST PATIENTS NEED; SELECT AND PREPROGRAM UP TO 14 DIFFERENT PANELS; TEST MENU INCLUDES SEVEN KENETIC ENZYME ASSAYS; AST,ALT,LDH,GT,ALK PHOS,CK,AND CK-MB,4 TWO POINT RATES, 15 COLORIMETRIC AND 4 POTENTIOMETRIC CHEMISTRIES; CALIBRATION REQUIRED EVERY 90 DAYS; Part Name Assigned by Controlling Agency: ANALYZER CLINICAL CHEMISTRY PROGRAMMABLE. 2 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com