PartsTable TECHNICAL DATA SHEET
NSN 6632-01-273-7501Government record, cited

Analyzer, Clinical Chemistry6632-01-273-7501

NSN 6632-01-273-7501 · NIIN 012737501 · Part number 1447X9
Ciba Corning Diagnostics Corp a Joint Venture · FSC 6632 — Medical Laboratory Analysis Instruments · FSG 66 — Instruments and Laboratory Equipment · CAGE 24143
Government record, cited
NSN 6632-01-273-7501 — this item is cataloged by the U.S. Government under National Stock Number 6632-01-273-7501. Manufacturer of record part number: 1447X9.
Also searched as  6632-01-273-7501 · 6632012737501 · NIIN 012737501 · 01-273-7501 · FSC 6632 Medical Laboratory Analysis Instruments · CAGE 24143 · 1447X9 · 6630-2101-0000 · 400E
Nearby stock numbers  ·
Features
  • Analyzer,clinical Chemistry — FSC 6632
  • Current Type: AC
  • Voltage in Volts: 110.0 AND 230.0
  • Frequency Rating: 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
  • 1 manufacturer part number on file
  • Manufacturer of record: Ciba Corning Diagnostics Corp a Joint Venture
Identification
  • NSN: 6632-01-273-7501
  • NIIN: 012737501
  • FSC: 6632 — Medical Laboratory Analysis Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 1447X9
  • Manufacturer: Ciba Corning Diagnostics Corp a Joint Venture
General Description

The Analyzer,clinical Chemistry, cataloged under National Stock Number 6632-01-273-7501, is classified within Federal Supply Class 6632 (Medical Laboratory Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Ciba Corning Diagnostics Corp a Joint Venture. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6632-01-273-7501
Primary Part Number1447X9
Item NameAnalyzer,clinical Chemistry
FSC / FSG6632 / 66 — Medical Laboratory Analysis Instruments
ManufacturerCiba Corning Diagnostics Corp a Joint Venture
StatusACTIVE
Current TypeAC
Voltage in Volts110.0 AND 230.0
Frequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 2
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6625-01-360-6520400E POSSIBLE MATCH
TEST SET,ELECTRICAL CABLE
Possible match (shared part number)Chatsworth Data Corp
2590-01-726-7709400E POSSIBLE MATCH
ARM ASSEMBLY,LIFT BLADE
Possible match (shared part number)Deere & Co
Cross-Reference Index
Part NumberManufacturer
1447X9 PRIMARY Ciba Corning Diagnostics Corp a Joint Venture (USA)
Reference documents
ReferenceMeaning
6630-2101-0000 6/9 Informative reference only
U.S. Government activity
400E 5/1 Secondary reference
Ciba Corning Diagnostics Corp a Joint Venture
Related Parts
6625-01-360-6520POSSIBLE MATCH
TEST SET,ELECTRICAL CABLE
400E
2590-01-726-7709POSSIBLE MATCH
ARM ASSEMBLY,LIFT BLADE
400E

Frequently Asked Questions

What is NSN 6632-01-273-7501?

NSN 6632-01-273-7501 is a Analyzer,clinical Chemistry, manufactured by Ciba Corning Diagnostics Corp a Joint Venture, classified under FSC 6632, Medical Laboratory Analysis Instruments. Status: active.

What part numbers are listed for NSN 6632-01-273-7501?

NSN 6632-01-273-7501 has 1 manufacturer part number on file: 1447X9 (Ciba Corning Diagnostics Corp a Joint Venture).

What NSN replaces 6632-01-273-7501?

2 possible matches (shared part number, not a government interchangeability claim): 6625-01-360-6520, 2590-01-726-7709. Verify interchangeability with system specifications before substitution.

What are the specifications of 1447X9?

Key specifications for 1447X9: Current Type: AC; Voltage in Volts: 110.0 AND 230.0; Special Features: MICROPROCESSOR-BASED AUTOMATIC ANALYZER HOUSED IN A SINGLE CABINET; CONTAINS A 60-POSITION TEST SAMPLE CAROUSEL,DUAL CUVETTE SAMPLING SYSTEM,GRATING MONOCHROMATOR AND DUAL PHOTOMETER,3 DIGITAL DILUTERS,FLOPPY-DISK DRIVE,16 CHARACTER THERMAL PRINTER,LED DISPLAY,AND TOUCHTONE KEYBOARD; PHOTOMETRIC RANGE 0-2 ABSORBANCE OVER THE RANGE OF 335 TO 700 NANOMTERS; AUTOMAIC CALIBRATION OF ABSORBANCE,WAVELENGTH,AND LINEARITY; 35 PREPROGRAMED DIAGNOSTIC TEST PLUS 23 USER-DEFINABLE PROGRAMS CAN BE ADDED; SYSTEM PROVIDES 320K OF DISK MEMORY WITH AN ADDITIONAL 80K OF PROM AND RAM ON THE COMPUTER PC CARDS; Frequency Rating: 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM. 3 specifications are documented in the U.S. Government catalog.

Is NSN 6632-01-273-7501 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com