The Timer,blood and Plasma Coagulati, cataloged under National Stock Number 6632-01-154-1697, is classified within Federal Supply Class 6632 (Analyzer,clinical Chemistry) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Becton, Dickinson and Co Dba Becton Dickinson & Co. Government technical data includes 3 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 10 commercial cross-references from 8 manufacturers, enabling identification through both NSN and commercial part number lookups. 9 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6632-01-154-1697 |
| Primary Part Number | 260415 |
| Item Name | Timer,blood and Plasma Coagulati |
| FSC / FSG | 6632 / 66 — Analyzer,clinical Chemistry |
| Manufacturer | Becton, Dickinson and Co Dba Becton Dickinson & Co |
| Status | ACTIVE |
| Exterior Container Weight | 20.00 POUNDS LBS |
| Unit of Issue Cube | 0.822 CUBIC FEET |
| General Characteristics Item Description | 115 VOLT,60 HZ; INCLUDES SIX WARMING WELLS; ONE REACTION WELL; ON-OFF SWITCH; RESET BUTTON; ELECTRIC PIPET; ELECTRO MECHANICAL CLOT SENSING DEVICE; 400 DISPOSABLE REACTION CUPS AND A 6 FT. 3-WIRE CORD WITH PLUG; FOR PERFORMING ALL ASSAYS THAT HAVE A FIBRIN END POINT INCLUDING PROTHROMBIN TIME,AND PARTIAL THROMBOPLASTIN TIME; FOR USE WITH BLOOD AND PLASMA COAGULATION TIMER REAGENT CUP,6630-01-032-4238 AND PIPET TIP,6640-00-902-0810 FT |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 60415 | Becton-Dickinson and Co Microbiology Systems Div (USA) |
| B4180-1 | Baxter Healthcare Corp Baxter Scientific Products Div Government Sales (USA) |
| 060-079 | Curtin Matheson Scientific Inc (USA) |
| BBL60415 | Becton-Dickinson and Co Microbiology Systems Div (USA) |
| B4180-1 | Cardinal Health 200, Llc (USA) |
| 02-658-100 | Fisher Scientific Company L.l.c. (USA) |
| FIBROMETER COAGULATION TIMER BBL | Becton-Dickinson and Co Microbiology Systems Div (USA) |
| 260415 PRIMARY | Becton, Dickinson and Co Dba Becton Dickinson & Co (USA) |
| BB60415 | Vwr Scientific Inc (USA) |
| 4554-D20 | Arthur H. Thomas Company (USA) |
NSN 6632-01-154-1697 is a Timer,blood and Plasma Coagulati, manufactured by Becton, Dickinson and Co Dba Becton Dickinson & Co, classified under FSC 6632 (Analyzer,clinical Chemistry). Status: active.
NSN 6632-01-154-1697 has 10 cross-referenced part numbers: 60415 (Becton-Dickinson and Co Microbiology Systems Div), B4180-1 (Baxter Healthcare Corp Baxter Scientific Products Div Government Sales), 060-079 (Curtin Matheson Scientific Inc), BBL60415 (Becton-Dickinson and Co Microbiology Systems Div), B4180-1 (Cardinal Health 200, Llc) and 5 more.
There are 9 known substitutes for 6632-01-154-1697: 5930-00-548-6448, 6680-00-786-3950, 8040-01-004-2705 and 6 more. Verify interchangeability with system specifications before substitution.
Key specifications for 260415: Part Name Assigned by Controlling Agency: TIMER BLOOD AND PLASMA COAGULATION FIBROMETER 115V 60HZ V; Exterior Container Weight: 20.00 POUNDS LBS; Unit of Issue Cube: 0.822 CUBIC FEET; General Characteristics Item Description: 115 VOLT,60 HZ; INCLUDES SIX WARMING WELLS; ONE REACTION WELL; ON-OFF SWITCH; RESET BUTTON; ELECTRIC PIPET; ELECTRO MECHANICAL CLOT SENSING DEVICE; 400 DISPOSABLE REACTION CUPS AND A 6 FT. 3-WIRE CORD WITH PLUG; FOR PERFORMING ALL ASSAYS THAT HAVE A FIBRIN END POINT INCLUDING PROTHROMBIN TIME,AND PARTIAL THROMBOPLASTIN TIME; FOR USE WITH BLOOD AND PLASMA COAGULATION TIMER REAGENT CUP,6630-01-032-4238 AND PIPET TIP,6640-00-902-0810 FT. 4 total characteristics are documented in the Federal Logistics Information System.