PRODUCT OVERVIEW

The 6630NCM162618 is a the manufacturer industrial component. This product is currently in active production with full OEM support. This part is cataloged in the Federal Logistics Information System (FLIS) under NSN 6632-01-234-6794, indicating validated use in U.S.

government and defense logistics supply chains. Available through authorized enterprise resellers and TPM (Third Party Maintenance) channels. Verify compatibility with your specific system configuration before ordering.

WHERE IT FITS
6630NCM162618
NSN: 6632-01-234-6794
FSC: 6632 — ANALYZER,CLINICAL CHEMISTRY
CAGE: 64616 — DEFENSE MEDICAL STANDARDIZATION BOARD (USA)
SPECIFICATIONS
Part Number6630NCM162618
NSN6632-01-234-6794
COMPONENT DIAGRAM
COMPONENT MAIN IC EDGE CONNECTOR No detailed specs available 6630NCM162618 TITLE COMPONENT PN 6630NCM162618 MFR 6630NCM162618
KEY FEATURES
SUPPLEMENTARY FEATURES: CONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED IN
VOLTAGE IN VOLTS: 120.0 AND 220.0
UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE: 17741
ACCESSORY COMPONENTS AND QUANTITY: ELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1
CURRENT TYPE: AC
FREQUENCY RATING: 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
TECHNICAL CHARACTERISTICS (FLIS)
SUPPLEMENTARY FEATURESCONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED IN
VOLTAGE IN VOLTS120.0 AND 220.0
PART NAME ASSIGNED BY CONTROLLING AGENCYANALYZER, CLINICAL CHEMISTRY
SPECIAL FEATURESMICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO RPM
UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE17741
ACCESSORY COMPONENTS AND QUANTITYELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1
CURRENT TYPEAC
FREQUENCY RATING50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
VERIFIED SUBSTITUTES & CROSS-REFERENCES 20
114786Interchangeable
interchangeable cross-reference
interchangeable
S1272Interchangeable
interchangeable cross-reference
interchangeable
252SPInterchangeable
interchangeable cross-reference
interchangeable
E12002CInterchangeable
interchangeable cross-reference
interchangeable
8930Interchangeable
interchangeable cross-reference
interchangeable
AT25451Interchangeable
interchangeable cross-reference
interchangeable
LIFECYCLE
StatusACTIVE
AvailabilityOEM and secondary market
RoHS CompliantEAR99Not HAZMAT
Ready to buy 6630NCM162618?
Compare prices from verified sellers on eBay
Buy on eBay →
As an eBay Partner, PartsTable may earn a commission. Your price is not affected.
FREQUENTLY ASKED QUESTIONS
What is 6630NCM162618?
6630NCM162618 is a 6630NCM162618.
What parts can replace 6630NCM162618?
There are 20 known substitutes for 6630NCM162618: 114786, S1272, 252SP and 17 more. Substitute compatibility should be verified for your specific system.
What is the NSN for 6630NCM162618?
6630NCM162618 is cataloged in the Federal Logistics Information System (FLIS) under NSN 6632-01-234-6794. This indicates validated use in U.S. government and defense supply chains.
Community Feedback
Comments (0)
No comments yet. Be the first to share what you know.
Leave a Comment
Comments are reviewed before appearing. You will receive an email to verify before your comment appears.

Request a Quote — 6630NCM162618