The Turbidimeter, cataloged under National Stock Number 6630-01-590-5210, is classified within Federal Supply Class 6630 (No Item Name Available) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Hach Company Dba Hach Co. Government technical data includes 2 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 7 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6630-01-590-5210 |
| Primary Part Number | 2100Q01 |
| Item Name | Turbidimeter |
| FSC / FSG | 6630 / 66 — No Item Name Available |
| Manufacturer | Hach Company Dba Hach Co |
| Status | ACTIVE |
| Functional Description | MEASURES WATER CLARITY AND DETECTS PARTICULATE MATTER THAT MAY ADVERSELY AFFECT WATER PURITY/QUALITY |
| Voltage in Volts and Current Type | 120.0 AC |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 6630NCM116133 | Defense Medical Standardization Board (USA) |
| 2100Q01 PRIMARY | Hach Company Dba Hach Co (USA) |
| 22925 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
| 2100Q | Thermo Fisher Scientific Pty Ltd Thermo Fisher Scientific Australia (AUS) |
| 010662 | Utilis Sa (FRA) |
NSN 6630-01-590-5210 is a Turbidimeter, manufactured by Hach Company Dba Hach Co, classified under FSC 6630 (No Item Name Available). Status: active.
NSN 6630-01-590-5210 has 5 cross-referenced part numbers: 6630NCM116133 (Defense Medical Standardization Board), 2100Q01 (Hach Company Dba Hach Co), 22925 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), 2100Q (Thermo Fisher Scientific Pty Ltd Thermo Fisher Scientific Australia), 010662 (Utilis Sa).
There are 7 known substitutes for 6630-01-590-5210: 9540-00-517-0664, 5935-00-518-7067, 8320-01-241-7393 and 4 more. Verify interchangeability with system specifications before substitution.
Key specifications for 2100Q01: Part Name Assigned by Controlling Agency: TURBIDIMETER PORTABLE; Functional Description: MEASURES WATER CLARITY AND DETECTS PARTICULATE MATTER THAT MAY ADVERSELY AFFECT WATER PURITY/QUALITY; Special Features: MEASUREMENT METHOD: RATIO TURBIDIMETRIC DETERMINATION USING A PRIMARY NEPHELOMETRIC LIGHT SCATTER SIGNAL (90 DEG) TO THE TRANSMITTED LIGHT SCATTER SIGNAL; RANGE: 0-1000 NTU; DETECTOR: SILICON PHOTODIODE; SAMPLE REQUIRED: 15 ML; SAMPLE CELLS: ROUND CELLS 60 X 25 MM (2.36 X 1 IN) BOROSILICATE GLASS WITH SCREW CAPS MM; Overall Length: 9.000 INCHES NOMINAL IN. 7 total characteristics are documented in the Federal Logistics Information System.