The Gene Amplifier,pcr, cataloged under National Stock Number 6630-01-461-0579, is classified within Federal Supply Class 6630 (Chemical Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Perkin Elmer Corp Applied Biosystems Div. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6630-01-461-0579 |
| Primary Part Number | N8050001 |
| Item Name | Gene Amplifier,pcr |
| FSC / FSG | 6630 / 66 — Chemical Analysis Instruments |
| Manufacturer | Perkin Elmer Corp Applied Biosystems Div |
| Status | ACTIVE |
| Functional Description | USED TO AMPLIFY NUCLEIC ACIDS FORGENE RESEARCH |
| Type/model Designation | 9700 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| N8050001 PRIMARY | Perkin Elmer Corp Applied Biosystems Div (USA) |
| Reference | Meaning |
|---|---|
| N805-0001 | 5/9 Secondary reference Perkinelmer |
| N805-001 | 5/9 Secondary reference Perkin Elmer Corp Applied Biosystems Div |
NSN 6630-01-461-0579 is a Gene Amplifier,pcr, manufactured by Perkin Elmer Corp Applied Biosystems Div, classified under FSC 6630, Chemical Analysis Instruments. Status: active.
NSN 6630-01-461-0579 has 1 manufacturer part number on file: N8050001 (Perkin Elmer Corp Applied Biosystems Div).
Key specifications for N8050001: Overall Height: 10.000 INCHES NOMINAL IN; Overall Length: 16.000 INCHES NOMINAL IN; Overall Width: 11.000 INCHES NOMINAL IN; Special Features: VARIABLE VOLTAGE AND FREQUENCY; ALL SOFTWARE OPERATION CONTROLLED BY FIVE SOFT KEYS, FOUR ARROW KEYS, STOP, ENTER, AND CLEAR KEYS, AND FULL NUMERIC KEYPAD; STORAGE OF 100 COMPLETE PCR METHODS; TIME AND TEMPERATURE PROTOCOLS DISPLAYED; DEFAULT PROGRAM OF PRE-PCR, 25 CYCLE PCR, AND POST PCR, CAN BE MODIFIED TO ANY PROTOCOL; RUNS MULTIPLE DIAGNOSTIC SOFTWARE ROUTINES; AUTO RESTART FUNCTION. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.