The Calibration Kit,clinical Chemist, cataloged under National Stock Number 6630-01-432-5151, is classified within Federal Supply Class 6630 (No Item Name Available) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc. Government technical data includes 1 verified specification, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6630-01-432-5151 |
| Primary Part Number | 120-4247 |
| Item Name | Calibration Kit,clinical Chemist |
| FSC / FSG | 6630 / 66 — No Item Name Available |
| Manufacturer | Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc |
| Status | ACTIVE |
| General Characteristics Item Description | CLINICAL CHEMISTRY CALIBRATOR KITNO. 6; CAN BE USED FOR 3 SEPARATE EVENTS; CONSISTS OF CHOLINESTERASE (CHE) AND CREATIVE KINASE MG (CKMB) |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 03-0557 | Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA) |
| 6630NCM030475 | Defense Medical Standardization Board (USA) |
| CALIBRATOR KIT 6 | Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc (USA) |
| 120-4247 PRIMARY | Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc (USA) |
| JJD 1204247 | Infolab, Llc Dba Infolab (USA) |
NSN 6630-01-432-5151 is a Calibration Kit,clinical Chemist, manufactured by Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc, classified under FSC 6630 (No Item Name Available). Status: active.
NSN 6630-01-432-5151 has 5 cross-referenced part numbers: 03-0557 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), 6630NCM030475 (Defense Medical Standardization Board), CALIBRATOR KIT 6 (Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc), 120-4247 (Ortho-Clinical Diagnostics Inc Dba Ortho-Clinical Diagnostics Inc), JJD 1204247 (Infolab, Llc Dba Infolab).
There are 2 known substitutes for 6630-01-432-5151: 5340-01-386-1567, 5365-01-603-1375. Verify interchangeability with system specifications before substitution.
Key specifications for 120-4247: General Characteristics Item Description: CLINICAL CHEMISTRY CALIBRATOR KITNO. 6; CAN BE USED FOR 3 SEPARATE EVENTS; CONSISTS OF CHOLINESTERASE (CHE) AND CREATIVE KINASE MG (CKMB); Part Name Assigned by Controlling Agency: CALIBRATION KIT CLINICAL CHEMISTRY ANALYZER 4S. 2 total characteristics are documented in the Federal Logistics Information System.