PartsTable TECHNICAL DATA SHEET
NSN 6630-01-340-5491Government record, cited

Analyzer, Alcohol6630-01-340-5491

NSN 6630-01-340-5491 · NIIN 013405491 · Part number RBT IV
Intoximeters, Inc Dba Intoximeters Inc · FSC 6630 — Chemical Analysis Instruments · FSG 66 — Instruments and Laboratory Equipment · CAGE 50949
Government record, cited
NSN 6630-01-340-5491 — this item is cataloged by the U.S. Government under National Stock Number 6630-01-340-5491. Manufacturer of record part number: RBT IV.
Also searched as  6630-01-340-5491 · 6630013405491 · NIIN 013405491 · 01-340-5491 · FSC 6630 Chemical Analysis Instruments · CAGE 50949 · RBT IV · RBT111 · 8M6 294142 · 12-0210-00
Nearby stock numbers  ·
Features
  • Analyzer,alcohol — FSC 6630
  • Analysis Cell Type: RAPID RESPONSE
  • Current Type: DC
  • Detection Range in Percent: +0.0 TO 999.0
  • Battery Type: DRY
  • Response Time: 2.0 MINUTES
  • Carrying Handle: INCLUDED
  • Battery Voltage Rating in Volts: 9.0 AND 12.0
Identification
  • NSN: 6630-01-340-5491
  • NIIN: 013405491
  • FSC: 6630 — Chemical Analysis Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: RBT IV
  • Manufacturer: Intoximeters, Inc Dba Intoximeters Inc
General Description

The Analyzer,alcohol, cataloged under National Stock Number 6630-01-340-5491, is classified within Federal Supply Class 6630 (Chemical Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Intoximeters, Inc Dba Intoximeters Inc. Government technical data includes 10 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6630-01-340-5491
Primary Part NumberRBT IV
Item NameAnalyzer,alcohol
FSC / FSG6630 / 66 — Chemical Analysis Instruments
ManufacturerIntoximeters, Inc Dba Intoximeters Inc
StatusACTIVE
Analysis Cell TypeRAPID RESPONSE
Current TypeDC
Detection Range in Percent+0.0 TO 999.0
Battery TypeDRY
Response Time2.0 MINUTES
Carrying HandleINCLUDED
Battery Voltage Rating in Volts9.0 AND 12.0
Corrosion Resistant FeatureNOT INCLUDED
BatteryINCLUDED
Battery Quantity2
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
RBT IV PRIMARY Intoximeters, Inc Dba Intoximeters Inc (USA)
Reference documents
ReferenceMeaning
RBT111 5/9 Secondary reference
Intoximeters, Inc Dba Intoximeters Inc
8M6 294142 5/1 Secondary reference
Naval Medical Material Support Command Detachment
12-0210-00 5/9 Secondary reference
Intoximeters, Inc Dba Intoximeters Inc
No interchangeability data on file.
Other items in FSC 6630 — Chemical Analysis Instruments
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6630-00-003-0889
6630-00-003-0889 · Item name not on file
6630-00-003-4363
6630-00-003-4363 · Item name not on file
6630-00-003-5588
6630-00-003-5588 · Item name not on file
6630-00-003-5589
TENSIOMETER,LIQUID,TORSION METHO
6630-00-003-8727
6630-00-003-8727 · Item name not on file
6630-00-004-1473
6630-00-004-1473 · Item name not on file
6630-00-004-7436
6630-00-004-7436 · Item name not on file
6630-00-004-7437
6630-00-004-7437 · Item name not on file

Frequently Asked Questions

What is NSN 6630-01-340-5491?

NSN 6630-01-340-5491 is a Analyzer,alcohol, manufactured by Intoximeters, Inc Dba Intoximeters Inc, classified under FSC 6630, Chemical Analysis Instruments. Status: active.

What part numbers are listed for NSN 6630-01-340-5491?

NSN 6630-01-340-5491 has 1 manufacturer part number on file: RBT IV (Intoximeters, Inc Dba Intoximeters Inc).

What are the specifications of RBT IV?

Key specifications for RBT IV: Overall Height: 4.500 INCHES NOMINAL IN; Analysis Cell Type: RAPID RESPONSE; Current Type: DC; Detection Range in Percent: +0.0 TO 999.0. 10 specifications are documented in the U.S. Government catalog.

Is NSN 6630-01-340-5491 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com