The Electrode,total Carbon Dioxide, cataloged under National Stock Number 6630-01-305-9573, is classified within Federal Supply Class 6630 (Chemical Analysis Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Nova Biomedical Corp. Government technical data includes 3 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6630-01-305-9573 |
| Primary Part Number | 07814 |
| Item Name | Electrode,total Carbon Dioxide |
| FSC / FSG | 6630 / 66 — Chemical Analysis Instruments |
| Manufacturer | Nova Biomedical Corp |
| Status | ACTIVE |
| Instrument Type for Which Designed | CARBON DIOXIDE ANALYZER |
| Body Material | GLASS |
| Body Length | 50.8 MILLIMETERS NOMINAL MM |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| B6350-421 | Cardinal Health 200, Llc (USA) |
| 07814 PRIMARY | Nova Biomedical Corp (USA) |
| Reference | Meaning |
|---|---|
| 89-08-07-012 | 5/1 Secondary reference Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa |
| A89G208 | 5/1 Secondary reference Department of the Army U S Army Medical Material Agency Mcmr-Mmo-Sa |
| B6350-421 | 5/9 Secondary reference Baxter Healthcare Corp Baxter Scientific Products Div Government Sales |
| 02611 | 5/9 Secondary reference Nova Biomedical Corp |
| 122-440 | 5/9 Secondary reference Curtin Matheson Scientific Inc |
NSN 6630-01-305-9573 is a Electrode,total Carbon Dioxide, manufactured by Nova Biomedical Corp, classified under FSC 6630, Chemical Analysis Instruments. Status: active.
NSN 6630-01-305-9573 has 2 manufacturer part numbers on file: B6350-421 (Cardinal Health 200, Llc), 07814 (Nova Biomedical Corp).
2 possible matches (shared part number, not a government interchangeability claim): 2590-01-598-4142, 5935-01-703-2161. Verify interchangeability with system specifications before substitution.
Key specifications for 07814: Instrument Type for Which Designed: CARBON DIOXIDE ANALYZER; Body Material: GLASS; Body Length: 50.8 MILLIMETERS NOMINAL MM; Special Features: BODY DIA 12.7 MM;FLOW CELL SLEEVE AND REPLACEABLE TC02 MEMBRANE;FITS INTO HSG O/A LG 50.8 MM;O/A WD 25.4 MM;USED W/NOVA 4 AND NOVA 4+4 ANALYZER MM. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.