The Chromatograph,gas, cataloged under National Stock Number 6630-01-055-2705, is classified within Federal Supply Class 6630 (No Item Name Available) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Agilent Technologies Inc Dba Agilent Technologies Inc Div Customer Service and Sales. Government technical data includes 1 verified specification, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 3 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6630-01-055-2705 |
| Primary Part Number | 5710A |
| Item Name | Chromatograph,gas |
| FSC / FSG | 6630 / 66 — No Item Name Available |
| Manufacturer | Agilent Technologies Inc Dba Agilent Technologies Inc Div Customer Service and Sales |
| Status | ACTIVE |
| General Characteristics Item Description | COLUMN OVEN-DOUBLE WALL-CAPACITY MAX. 60 FT. X 1/8 IN. OD OR 30 FT. OF 1/4 IN. OD COLUMNS,TEMP RANGE -50 DEG C. TO 399 DEG C.,TEMP PROGRAMMER-AUTO DIGITAL,REPEATABILITY 0.1 PCT,DETECTOR,INJECTOR AND AUXILIARY TEMP CONTROLLERS,FLAME IONIZATION DETECTOR-DUAL GROUNDED JET,ELECTROMETER-TWO STAGE BIPOLAR DESIGN,OUTPUT-RECORDER 1MV FULL SCALE WITH BINARY OUTPUT ATTENUATOR 1-1024,COMPUTER-10V PER SCALE,THERMAL CONDUCTIVITY DETECTOR-DUAL,FOUR PASSIVATED TUNGSTENRHENIUM FILAMENTS,ELECTRON CAPTURE DETECTOR-TYPE-15 MC NI63SOURCE PLATED DIRECTLY ON COAXIAL CHAMBER,SIZE-18.500 X 22.250 X 19.000,POWER CONSUMPTION-1800 VA MAX.,115-230V PLUS OR MINUS SINGLE OR SPLIT PHASE,48-66 HZ. V |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 6630-1716-0752 | Defense Supply Center Richmond Industrial Plant Equipment /dla/ (USA) |
| 5710A | Agilent Technologies, Inc. Div Little Falls Anlytical Site (USA) |
| 5710A PRIMARY | Agilent Technologies Inc Dba Agilent Technologies Inc Div Customer Service and Sales (USA) |
| 5710A | Hewlett-Packard Company Dba HP (USA) |
NSN 6630-01-055-2705 is a Chromatograph,gas, manufactured by Agilent Technologies Inc Dba Agilent Technologies Inc Div Customer Service and Sales, classified under FSC 6630 (No Item Name Available). Status: active.
NSN 6630-01-055-2705 has 4 cross-referenced part numbers: 6630-1716-0752 (Defense Supply Center Richmond Industrial Plant Equipment /dla/), 5710A (Agilent Technologies, Inc. Div Little Falls Anlytical Site), 5710A (Agilent Technologies Inc Dba Agilent Technologies Inc Div Customer Service and Sales), 5710A (Hewlett-Packard Company Dba HP).
There are 3 known substitutes for 6630-01-055-2705: 6630-01-149-3999, 6630-01-268-9610, 4910-01-725-9562. Verify interchangeability with system specifications before substitution.
Key specifications for 5710A: General Characteristics Item Description: COLUMN OVEN-DOUBLE WALL-CAPACITY MAX. 60 FT. X 1/8 IN. OD OR 30 FT. OF 1/4 IN. OD COLUMNS,TEMP RANGE -50 DEG C. TO 399 DEG C.,TEMP PROGRAMMER-AUTO DIGITAL,REPEATABILITY 0.1 PCT,DETECTOR,INJECTOR AND AUXILIARY TEMP CONTROLLERS,FLAME IONIZATION DETECTOR-DUAL GROUNDED JET,ELECTROMETER-TWO STAGE BIPOLAR DESIGN,OUTPUT-RECORDER 1MV FULL SCALE WITH BINARY OUTPUT ATTENUATOR 1-1024,COMPUTER-10V PER SCALE,THERMAL CONDUCTIVITY DETECTOR-DUAL,FOUR PASSIVATED TUNGSTENRHENIUM FILAMENTS,ELECTRON CAPTURE DETECTOR-TYPE-15 MC NI63SOURCE PLATED DIRECTLY ON COAXIAL CHAMBER,SIZE-18.500 X 22.250 X 19.000,POWER CONSUMPTION-1800 VA MAX.,115-230V PLUS OR MINUS SINGLE OR SPLIT PHASE,48-66 HZ. V; Special Features: CONTAINS RHENIUM. 2 total characteristics are documented in the Federal Logistics Information System.