The Tester,flash Point, cataloged under National Stock Number 6630-00-359-9787, is classified within Federal Supply Class 6630 (No Item Name Available) of the Instruments and Laboratory Equipment group. The primary manufacturer of record is Fisher Scientific Company L.l.c.. Government technical data includes 11 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 6 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 10 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 6630-00-359-9787 |
| Primary Part Number | 13-528 |
| Item Name | Tester,flash Point |
| FSC / FSG | 6630 / 66 — No Item Name Available |
| Manufacturer | Fisher Scientific Company L.l.c. |
| Status | CANCELLED |
| Accessory Components and Quantity | BOARD HEAT-ROC 1,BURNER TEST FLAMG 1,CLAMP THERMOMETER 1,CUP PLATFORM 1,DISC HEAT ROC 1,HEATER FUL-CONTROL W/BUILT-IN AUTO TRANSFORMER 1,HOOK THEROMETER 1,PLATE CAST IRON 1 |
| Thermometer Quantity | 1 |
| Heating Element Voltage in Volts | 115.0 |
| Specification/standard Data | 81346-ASTM-D92 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
| Heating Element Current Type | AC |
| Design Type | OPEN |
| Heating Method | ELECTRICAL |
| Test Unit Quantity | 1 |
| Heating Element Phase | SINGLE |
| Thermometer Range | +20.0 TO 760.0 DEG FAHRENHEIT |
| Heating Element Frequency in Hertz | 50.0 OR 60.0 |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 13-528 | Fisher Scientific Company L.l.c. (USA) |
| 176-982 | Curtin Matheson Scientific Inc (USA) |
| 74582 | Precision Scientific Petroleum Instruments Co (USA) |
| 16262P | Curtin Matheson Scientific Inc (USA) |
| D92 | American Society for Testing and Materials Dba Astm International (USA) |
| G18080 | Manostat Corp (USA) |
NSN 6630-00-359-9787 is a Tester,flash Point, manufactured by Fisher Scientific Company L.l.c., classified under FSC 6630 (No Item Name Available). Status: cancelled.
NSN 6630-00-359-9787 has 6 cross-referenced part numbers: 13-528 (Fisher Scientific Company L.l.c.), 176-982 (Curtin Matheson Scientific Inc), 74582 (Precision Scientific Petroleum Instruments Co), 16262P (Curtin Matheson Scientific Inc), D92 (American Society for Testing and Materials Dba Astm International) and 1 more.
There are 10 known substitutes for 6630-00-359-9787: 5815-00-125-4974, 5306-00-225-8503, 5977-00-237-1615 and 7 more. Verify interchangeability with system specifications before substitution.
Key specifications for 13-528: Accessory Components and Quantity: BOARD HEAT-ROC 1,BURNER TEST FLAMG 1,CLAMP THERMOMETER 1,CUP PLATFORM 1,DISC HEAT ROC 1,HEATER FUL-CONTROL W/BUILT-IN AUTO TRANSFORMER 1,HOOK THEROMETER 1,PLATE CAST IRON 1; Thermometer Quantity: 1; Heating Element Voltage in Volts: 115.0; Specification/standard Data: 81346-ASTM-D92 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION. 11 total characteristics are documented in the Federal Logistics Information System.
NSN 6630-00-359-9787 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.