PartsTable TECHNICAL DATA SHEET
NSN 6625-01-590-3333Government record, cited

Multimeter6625-01-590-3333

NSN 6625-01-590-3333 · NIIN 015903333 · Part number U1732A
Keysight Technologies Inc · FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment · CAGE 7ZXR5
Government record, cited
NSN 6625-01-590-3333 — this item is cataloged by the U.S. Government under National Stock Number 6625-01-590-3333. Manufacturer of record part number: U1732A.
Also searched as  6625-01-590-3333 · 6625015903333 · NIIN 015903333 · 01-590-3333 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · CAGE 7ZXR5 · U1732A
Nearby stock numbers  ·
Features
  • Multimeter — FSC 6625
  • Frequency Rating: 1.0 KILOHERTZ MAXIMUM
  • 1 manufacturer part number on file
  • Manufacturer of record: Keysight Technologies Inc
Identification
  • NSN: 6625-01-590-3333
  • NIIN: 015903333
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: U1732A
  • Manufacturer: Keysight Technologies Inc
General Description

The Multimeter, cataloged under National Stock Number 6625-01-590-3333, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Keysight Technologies Inc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6625-01-590-3333
Primary Part NumberU1732A
Item NameMultimeter
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
ManufacturerKeysight Technologies Inc
StatusACTIVE
Frequency Rating1.0 KILOHERTZ MAXIMUM
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
U1732A PRIMARY Keysight Technologies Inc (USA)
Reference documents
ReferenceMeaning
U1732A 3/9 Design control — primary reference
Keysight Technologies, Inc.
No interchangeability data on file.
Other items in FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6625-00-000-0309
6625-00-000-0309 · Item name not on file
6625-00-000-0480
6625-00-000-0480 · Item name not on file
6625-00-001-1338
6625-00-001-1338 · Item name not on file
6625-00-001-1341
6625-00-001-1341 · Item name not on file
6625-00-001-1371
6625-00-001-1371 · Item name not on file
6625-00-001-1373
6625-00-001-1373 · Item name not on file
6625-00-001-1374
6625-00-001-1374 · Item name not on file
6625-00-001-1377
SWEEP GENERATOR SUBASSEMBLY

Frequently Asked Questions

What is NSN 6625-01-590-3333?

NSN 6625-01-590-3333 is a Multimeter, manufactured by Keysight Technologies Inc, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What part numbers are listed for NSN 6625-01-590-3333?

NSN 6625-01-590-3333 has 1 manufacturer part number on file: U1732A (Keysight Technologies Inc).

What are the specifications of U1732A?

Key specifications for U1732A: Special Features: AUTO AND MANUAL RANGING MODES; 1S/DUT MANUAL RANGE RESPONSE TIME; 9V ALKALINE BATTERY POWER SUPPLY; OPERATES IN 0 TO 40 DEG CELCIUS TO 70 PERCENT RH; WEIGHT 330 GRAMS; DIMENSIONS IN MM: 184 X 87 X 41, H X W X D V; Frequency Rating: 1.0 KILOHERTZ MAXIMUM. 1 specification is documented in the U.S. Government catalog.

Is NSN 6625-01-590-3333 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com