The Test Set,electrical Cable, cataloged under National Stock Number 6625-01-465-8089, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 6 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6625-01-465-8089 |
| Item Name | Test Set,electrical Cable |
| FSC / FSG | 6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments |
| Status | ACTIVE |
| AC Voltage Rating | 90.0 VOLTS MINIMUM AND 260.0 VOLTS MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| Major Components | INTERFACE CABLES 14EA; RS-232 CABLE; TO AIRCAFT POWER, CABLE |
| Functional Description | PROVIDE A CONTINUOUS TEST MODE DURING FAULT ISOLATION OF THE 1553 BUS NETWORK, FOR THE PURPOSE OF DETECTING INTERMITTENT FAULTS AS WELL AS HARD FAILURES, IN THE C-17 AIRCRAFT; THIS WILLHELP PREVENT ANY COMMUNICATION PROBLEMS AMONG THE LRU'S |
| Enclosure Feature | SINGLE ITEM W/HOUSING |
| Frequency Rating | 60.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| Test Type for Which Designed | DETECTION OF INTERMITTENT AND HARD FAULTS ON THE 1553 DATA BUS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | EA |
| Acquisition advice code | CU |
| Reference | Meaning |
|---|---|
| 85T-F16/MUXBUS-T001-00A | 3/2 Design control — primary reference U.S. Government activity |
NSN 6625-01-465-8089 is a Test Set,electrical Cable, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.
Key specifications for 6625-01-465-8089: AC Voltage Rating: 90.0 VOLTS MINIMUM AND 260.0 VOLTS MAXIMUM LOCATION NOT OTHERWISE SPECIFIED; Major Components: INTERFACE CABLES 14EA; RS-232 CABLE; TO AIRCAFT POWER, CABLE; Special Features: PROVIDES THE A.C. TESTS TO MEASURE IMPEDANCE OF THE COMPLETE BUS INCLUDING ALL LOADS ON STUBS; DC TEST MEASURES RESISTANCE OF THE BUS WIRING; Functional Description: PROVIDE A CONTINUOUS TEST MODE DURING FAULT ISOLATION OF THE 1553 BUS NETWORK, FOR THE PURPOSE OF DETECTING INTERMITTENT FAULTS AS WELL AS HARD FAILURES, IN THE C-17 AIRCRAFT; THIS WILLHELP PREVENT ANY COMMUNICATION PROBLEMS AMONG THE LRU'S. 6 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.