The Meter,electrical Frequency, cataloged under National Stock Number 6625-01-346-0065, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6625-01-346-0065 |
| Item Name | Meter,electrical Frequency |
| FSC / FSG | 6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Meter Body Diameter Behind Mounting Flange | 3.970 INCHES NOMINAL IN |
| FSC Application Data | TEST SET,ELECT. EQUIP. |
| Indicator Type | DIAL W/POINTER |
| Mounting Arrangement Style | FOUR HOLE/STUD RECTANGULAR/SQUARE |
| Meter Depth Behind Mounting Flange | 3.790 INCHES NOMINAL IN |
| Accuracy in Percent | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.360 INCHES MINIMUM AND 3.390 INCHES MAXIMUM IN |
| Power Source | EXTERNAL |
| Style Designator | RECTANGULAR FLUSH MTG |
| Mounting Hole Diameter | 0.313 INCHES NOMINAL IN |
| Features Provided | ZERO ADJUSTER |
| Environmental Protection | DUST RESISTANT AND HUMIDITY RESISTANT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 3.360 INCHES MINIMUM AND 3.390 INCHES MAXIMUM IN |
| Material | STEEL |
| Measurement Range | +55.0 TO 65.0 HERTZ SINGLE INDICATOR SINGLE RANGE |
| Nuclear Hardness Critical Feature | NONHARDENED |
| Installation Design | PANEL |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | EA |
| Acquisition advice code | JF |
| Reference | Meaning |
|---|---|
| 141-001059 | 3/9 Design control — primary reference International Switchboard Corp Div of Equus Power Systems Corp |
| 103-011-LS | 5/1 Secondary reference Yokogawa Corporation of America |
NSN 6625-01-346-0065 is a Meter,electrical Frequency, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 6625-01-346-0066. Verify interchangeability with system specifications before substitution.
Key specifications for 6625-01-346-0065: Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Meter Body Diameter Behind Mounting Flange: 3.970 INCHES NOMINAL IN; Overall Height: 4.330 INCHES NOMINAL IN; FSC Application Data: TEST SET,ELECT. EQUIP.. 18 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.