NSN 6625-01-302-0895Government record, cited

Meter, Special Scale6625-01-302-0895

NSN 6625-01-302-0895 · NIIN 013020895 · Part number 21814742A21AS1201C00
General Electric Company Dba Ge · FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment · CAGE 02989
Government record, cited
NSN 6625-01-302-0895 — this item is cataloged by the U.S. Government under National Stock Number 6625-01-302-0895. Manufacturer of record part number: 21814742A21AS1201C00.
Also searched as  6625-01-302-0895 · 6625013020895 · NIIN 013020895 · 01-302-0895 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · CAGE 02989 · 21814742A21AS1201C00 · 218A4742A21AS1201C00 · 218A4742A21AS1201C00
Nearby stock numbers  ·
Features
  • Meter,special Scale — FSC 6625
  • Mounting Facility Type and Quantity: 4 SCREW AND 4 UNTHREADED HOLE(S)
  • Meter Body Diameter Behind Mounting Flange: 3.970 INCHES NOMINAL IN
  • FSC Application Data: TEST SET,ELECT. EQUIP.
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: FOUR HOLE/STUD RECTANGULAR/SQUARE
  • Circuit Attachment Method and Quantity: 2 THREADED STUD
  • Meter Depth Behind Mounting Flange: 3.790 INCHES NOMINAL IN
Identification
  • NSN: 6625-01-302-0895
  • NIIN: 013020895
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 21814742A21AS1201C00
  • Manufacturer: General Electric Company Dba Ge
General Description

The Meter,special Scale, cataloged under National Stock Number 6625-01-302-0895, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is General Electric Company Dba Ge. Government technical data includes 27 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6625-01-302-0895
Primary Part Number21814742A21AS1201C00
Item NameMeter,special Scale
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
ManufacturerGeneral Electric Company Dba Ge
StatusACTIVE
Mounting Facility Type and Quantity4 SCREW AND 4 UNTHREADED HOLE(S)
Meter Body Diameter Behind Mounting Flange3.970 INCHES NOMINAL IN
FSC Application DataTEST SET,ELECT. EQUIP.
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
Circuit Attachment Method and Quantity2 THREADED STUD
Meter Depth Behind Mounting Flange3.790 INCHES NOMINAL IN
Circuit Current for Which DesignedDC
Accuracy in Percent-1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
Center to Center Distance Between Mounting Facilities Parallel to Length3.375 INCHES NOMINAL IN
Panel for Which DesignedNONMAGNETIC
Dielectric Withstanding Voltage in Volts2300.0
Style DesignatorRECTANGULAR FLUSH MTG
Mounting Hole Diameter0.312 INCHES NOMINAL IN
Features ProvidedZERO ADJUSTER
Scale Division Quantity40 SINGLE INDICATOR SINGLE RANGE
ColorUNABLE TO DECODE
Pointer ColorBLACK SINGLE INDICATOR SINGLE RANGE
Environmental ProtectionSHOCK RESISTANT AND VIBRATION RESISTANT AND WATERTIGHT
Unable to DecodeUNABLE TO DECODE
Center to Center Distance Between Mounting Facilities Parallel to Width3.375 INCHES NOMINAL IN
Dial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
MaterialSTEEL
Sensitivity Rating10.0 VOLTS
Scale Graduation TypeLINEAR SINGLE INDICATOR SINGLE RANGE
Nuclear Hardness Critical FeatureNONHARDENED
Installation DesignPANEL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Shelf Life Code0
Criticality CodeX
Unit of IssueEA
Acquisition advice codeX
Weight2.0000 lbs
Cube0.1700 cu ft
Cross-Reference Index
Part NumberManufacturer
21814742A21AS1201C00 PRIMARY General Electric Company Dba Ge (USA)
Reference documents
ReferenceMeaning
218A4742A21AS1201C00 5/9 Secondary reference
Yokogawa Corporation of America
218A4742A21AS1201C00 C/1 Advisory reference — outside the item-of-supply concept
General Electric Company Dba Ge
No interchangeability data on file.
Other items in FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6625-00-000-0309
6625-00-000-0309 · Item name not on file
6625-00-000-0480
6625-00-000-0480 · Item name not on file
6625-00-001-1338
6625-00-001-1338 · Item name not on file
6625-00-001-1341
6625-00-001-1341 · Item name not on file
6625-00-001-1371
6625-00-001-1371 · Item name not on file
6625-00-001-1373
6625-00-001-1373 · Item name not on file
6625-00-001-1374
6625-00-001-1374 · Item name not on file
6625-00-001-1377
SWEEP GENERATOR SUBASSEMBLY

Frequently Asked Questions

What is NSN 6625-01-302-0895?

NSN 6625-01-302-0895 is a Meter,special Scale, manufactured by General Electric Company Dba Ge, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What part numbers are listed for NSN 6625-01-302-0895?

NSN 6625-01-302-0895 has 1 manufacturer part number on file: 21814742A21AS1201C00 (General Electric Company Dba Ge).

What are the specifications of 21814742A21AS1201C00?

Key specifications for 21814742A21AS1201C00: Mounting Facility Type and Quantity: 4 SCREW AND 4 UNTHREADED HOLE(S); Meter Body Diameter Behind Mounting Flange: 3.970 INCHES NOMINAL IN; Overall Height: 4.330 INCHES NOMINAL IN; FSC Application Data: TEST SET,ELECT. EQUIP.. 27 specifications are documented in the U.S. Government catalog.

Is NSN 6625-01-302-0895 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com