The Shunt,instrument, cataloged under National Stock Number 6625-01-161-0614, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 12 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6625-01-161-0614 |
| Item Name | Shunt,instrument |
| FSC / FSG | 6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments |
| Status | ACTIVE |
| FSC Application Data | TEST SET,ELECT. EQUIP. |
| Usage Design | EXTERNAL |
| Accuracy in Percent | -0.5 TO 0.5 AT FULL SCALE |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 4.108 INCHES MINIMUM AND 4.142 INCHES MAXIMUM IN |
| Mounting Method | UNTHREADED HOLE(S) |
| Unthreaded Mounting Hole Diameter | 0.200 INCHES NOMINAL IN |
| Terminal Location | TOP |
| Current Rating and Type | 4.472 AMPERES NOMINAL DC |
| Voltage Drop in Millivolts | 4.5 NOMINAL |
| Terminal Type and Quantity | 4 THREADED STUD |
| Mounting Provision Quantity | 2 |
| Furnished Items and Quantity | NUT 4; WASHER 8 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | EA |
| Acquisition advice code | J |
| Reference | Meaning |
|---|---|
| G644951 | 5/9 Secondary reference Lucent Technologies Inc Advanced Technology Systems |
| KS-20401L2 | 3/9 Design control — primary reference American Telephone and Telegraph Co |
NSN 6625-01-161-0614 is a Shunt,instrument, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.
Key specifications for 6625-01-161-0614: Overall Height: 1.550 INCHES MAXIMUM IN; FSC Application Data: TEST SET,ELECT. EQUIP.; Usage Design: EXTERNAL; Accuracy in Percent: -0.5 TO 0.5 AT FULL SCALE. 12 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.