The Calibrator,voltage, cataloged under National Stock Number 6625-01-090-0625, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 6 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6625-01-090-0625 |
| Item Name | Calibrator,voltage |
| FSC / FSG | 6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments |
| Status | ACTIVE |
| AC Voltage Rating | 100.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
| Instrument Calibration Range | 0.1 MV TO 119.9999 VOLTS AND 10.0 HZ TO 1.2 MHZ MHz |
| Mounting Method | BENCH |
| Calibration Accuracy Rating | AMPLITUDE ERROR HAS 2 RANGES,PORM 3.0 PCT OR PORM 0.3 PCT,ACCURACY 90 DAYS 23.0 DEGREES CELSIUS PORM 5.0 DEGREES CELSIUS AFTER 1.0 HR WARM UP,ABSOLUTE,TRACEABLE TO NBS STANDARDS |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| Calibration Range Quantity | 11 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Shelf Life Code | 0 |
| Criticality Code | X |
| Unit of Issue | EA |
| Acquisition advice code | VH |
| Weight | 61.0000 lbs |
| Cube | 3.9948 cu ft |
| Reference | Meaning |
|---|---|
| 5200A0PT05 | 5/9 Secondary reference U.S. Government activity |
| JF5200A0PT05RACK | 5/2 Secondary reference U.S. Government activity |
| 5200A-05 | 3/2 Design control — primary reference U.S. Government activity |
NSN 6625-01-090-0625 is a Calibrator,voltage, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.
Key specifications for 6625-01-090-0625: Overall Height: 7.000 INCHES NOMINAL IN; AC Voltage Rating: 100.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM; Instrument Calibration Range: 0.1 MV TO 119.9999 VOLTS AND 10.0 HZ TO 1.2 MHZ MHz; Mounting Method: BENCH. 6 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.