PartsTable TECHNICAL DATA SHEET
NSN 6625-01-021-1313Government record, cited

Ammeter6625-01-021-1313

NSN 6625-01-021-1313 · NIIN 010211313
FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment
Government record, cited
Also searched as  6625-01-021-1313 · 6625010211313 · NIIN 010211313 · 01-021-1313 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · MR49W80AFAAH · MR49W080AFAAH · A57878 · MIL-DTL-16034/4 · 496-008
Nearby stock numbers  ·
Features
  • Ammeter — FSC 6625
  • Circuit Construction Type: NONELECTRONIC
  • Mounting Facility Type and Quantity: 4 SCREW AND 4 UNTHREADED HOLE(S)
  • Meter Body Diameter Behind Mounting Flange: 3.980 INCHES MAXIMUM IN
  • FSC Application Data: TEST SET,ELECT. EQUIP.
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: FOUR HOLE/STUD RECTANGULAR/SQUARE
  • Circuit Attachment Method and Quantity: 2 THREADED STUD
Identification
  • NSN: 6625-01-021-1313
  • NIIN: 010211313
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Ammeter, cataloged under National Stock Number 6625-01-021-1313, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6625-01-021-1313
Item NameAmmeter
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
StatusACTIVE
Circuit Construction TypeNONELECTRONIC
Mounting Facility Type and Quantity4 SCREW AND 4 UNTHREADED HOLE(S)
Meter Body Diameter Behind Mounting Flange3.980 INCHES MAXIMUM IN
FSC Application DataTEST SET,ELECT. EQUIP.
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
Circuit Attachment Method and Quantity2 THREADED STUD
Meter Depth Behind Mounting Flange10.000 INCHES MAXIMUM IN
Circuit Current for Which DesignedAC
Movement TypeMOVING IRON VANE
Accuracy in Percent-1.5 TO 1.5 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
Center to Center Distance Between Mounting Facilities Parallel to Length3.373 INCHES MINIMUM AND 3.379 INCHES MAXIMUM IN
Special Test FeaturesCONFORMS TO MIL-M-16034/4
Panel for Which DesignedMAGNETIC
Supplementary FeaturesDAMPING FACTOR 3; RESPONSE TIME 2.5 SECONDS MAXIMUM
Power SourceEXTERNAL
Style DesignatorRECTANGULAR FLUSH MTG
Mounting Hole Diameter0.312 INCHES NOMINAL IN
Features ProvidedZERO ADJUSTER
Specification/standard Data81349-MIL-M-16034/4 GOVERNMENT SPECIFICATION
Movement Suspension MethodTAUT BAND
ColorUNABLE TO DECODE
Pointer ColorBLACK SINGLE INDICATOR SINGLE RANGE
Environmental ProtectionCOLD RESISTANT AND HEAT RESISTANT AND HUMIDITY PROOF AND VIBRATION RESISTANT
Frequency Rating400.0 HERTZ NOMINAL
Center to Center Distance Between Mounting Facilities Parallel to Width3.373 INCHES MINIMUM AND 3.379 INCHES MAXIMUM IN
Test Data Document81349-MIL-M-16034 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Shelf Life Code0
Criticality CodeX
Unit of IssueEA
Acquisition advice codeJF
Weight3.0000 lbs
Cube0.2690 cu ft
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6515-01-471-7877496008 POSSIBLE MATCH
INTRODUCER KIT,CATHETER,PERCUTAN
Possible match (shared part number)Maxxim Medical Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MR49W80AFAAH C/1 Advisory reference — outside the item-of-supply concept
General Electric Co Outdoor Breaker Business Section
MR49W080AFAAH 2/2 Government specification standardization
U.S. Government activity
A57878 C/1 Advisory reference — outside the item-of-supply concept
Nei Peebles-Electric Products Inc
MIL-DTL-16034/4 4/1 Identification reference
U.S. Government activity
496-008 C/1 Advisory reference — outside the item-of-supply concept
Jewell Instruments, Llc Dba Modutec Use CAGE Code 33005 for Cataloging
MIL-M-16034/4 5/9 Secondary reference
U.S. Government activity
MR49080AFAAH C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
Related Parts
6515-01-471-7877POSSIBLE MATCH
INTRODUCER KIT,CATHETER,PERCUTAN
496008

Frequently Asked Questions

What is NSN 6625-01-021-1313?

NSN 6625-01-021-1313 is a Ammeter, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What NSN replaces 6625-01-021-1313?

1 possible match (shared part number, not a government interchangeability claim): 6515-01-471-7877. Verify interchangeability with system specifications before substitution.

What are the specifications of 6625-01-021-1313?

Key specifications for 6625-01-021-1313: Circuit Construction Type: NONELECTRONIC; Mounting Facility Type and Quantity: 4 SCREW AND 4 UNTHREADED HOLE(S); Meter Body Diameter Behind Mounting Flange: 3.980 INCHES MAXIMUM IN; Overall Height: 4.250 INCHES MINIMUM AND 4.750 INCHES MAXIMUM IN. 27 specifications are documented in the U.S. Government catalog.

Is NSN 6625-01-021-1313 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com