PartsTable TECHNICAL DATA SHEET
NSN 6625-01-019-6650Government record, cited

Meter, Special Scale6625-01-019-6650

NSN 6625-01-019-6650 · NIIN 010196650
FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment
Government record, cited
Also searched as  6625-01-019-6650 · 6625010196650 · NIIN 010196650 · 01-019-6650 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · 53-5424-8502 · 503X
Nearby stock numbers  ·
Features
  • Meter,special Scale — FSC 6625
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S)
  • Meter Body Diameter Behind Mounting Flange: 2.790 INCHES MAXIMUM IN
  • FSC Application Data: TEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED
  • Operating Voltage Rating in Volts: 120.0 AC NOMINAL
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: FOUR HOLE/STUD RECTANGULAR/SQUARE
  • Circuit Attachment Method and Quantity: 17 SCREW
Identification
  • NSN: 6625-01-019-6650
  • NIIN: 010196650
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Meter,special Scale, cataloged under National Stock Number 6625-01-019-6650, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6625-01-019-6650
Item NameMeter,special Scale
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
StatusACTIVE
Mounting Facility Type and Quantity4 THREADED STUD(S)
Meter Body Diameter Behind Mounting Flange2.790 INCHES MAXIMUM IN
FSC Application DataTEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED
Operating Voltage Rating in Volts120.0 AC NOMINAL
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleFOUR HOLE/STUD RECTANGULAR/SQUARE
Circuit Attachment Method and Quantity17 SCREW
Meter Depth Behind Mounting Flange5.500 INCHES MAXIMUM IN
Circuit Current for Which DesignedAC
Accuracy in Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES
Center to Center Distance Between Mounting Facilities Parallel to Length4.000 INCHES NOMINAL IN
Mounting Stud Diameter0.138 INCHES NOMINAL IN
Panel for Which DesignedNONMAGNETIC
Style DesignatorRECTANGULAR FLUSH MTG
Features ProvidedADJUSTABLE INDEX POINTER AND ZERO ADJUSTER
Scale Division Quantity30 SINGLE INDICATOR SECOND RANGE
Scale Division Quantity60 SINGLE INDICATOR FIRST RANGE
ColorUNABLE TO DECODE
Pointer ColorBLACK SINGLE INDICATOR ALL RANGES
Mounting Stud Length0.500 INCHES NOMINAL IN
Frequency Rating50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM
Unable to DecodeUNABLE TO DECODE
Center to Center Distance Between Mounting Facilities Parallel to Width3.560 INCHES NOMINAL IN
Dial Scale Marking ColorBLACK SINGLE INDICATOR ALL RANGES
Special MarkingsTHERMOCOUPLE COPPER
MaterialPLASTIC PHENOLIC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Shelf Life Code0
Criticality CodeX
Unit of IssueEA
Acquisition advice codeY
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
53-5424-8502 3/9 Design control — primary reference
U.S. Government activity
503X 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6625-00-000-0309
6625-00-000-0309 · Item name not on file
6625-00-000-0480
6625-00-000-0480 · Item name not on file
6625-00-001-1338
6625-00-001-1338 · Item name not on file
6625-00-001-1341
6625-00-001-1341 · Item name not on file
6625-00-001-1371
6625-00-001-1371 · Item name not on file
6625-00-001-1373
6625-00-001-1373 · Item name not on file
6625-00-001-1374
6625-00-001-1374 · Item name not on file
6625-00-001-1377
SWEEP GENERATOR SUBASSEMBLY

Frequently Asked Questions

What is NSN 6625-01-019-6650?

NSN 6625-01-019-6650 is a Meter,special Scale, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What are the specifications of 6625-01-019-6650?

Key specifications for 6625-01-019-6650: Mounting Facility Type and Quantity: 4 THREADED STUD(S); Meter Body Diameter Behind Mounting Flange: 2.790 INCHES MAXIMUM IN; Overall Height: 4.270 INCHES MAXIMUM IN; FSC Application Data: TEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED. 26 specifications are documented in the U.S. Government catalog.

Is NSN 6625-01-019-6650 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com