PartsTable TECHNICAL DATA SHEET
NSN 6625-00-899-3652Government record, cited

Voltmeter6625-00-899-3652

NSN 6625-00-899-3652 · NIIN 008993652
FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment
Government record, cited
Also searched as  6625-00-899-3652 · 6625008993652 · NIIN 008993652 · 00-899-3652 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · MR36B030DCVVR · MIL-M-10304/11 · MIL-PRF-10304/11
Nearby stock numbers  ·
Features
  • Voltmeter — FSC 6625
  • Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S)
  • Meter Body Diameter Behind Mounting Flange: 2.800 INCHES MAXIMUM IN
  • FSC Application Data: TEST SET ELECTRONIC
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: THREE HOLE/STUD BOLT CIRCLE
  • Circuit Attachment Method and Quantity: 2 THREADED STUD AND 2 SOLDER LUG
  • Meter Depth Behind Mounting Flange: 2.450 INCHES MAXIMUM IN
Identification
  • NSN: 6625-00-899-3652
  • NIIN: 008993652
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Voltmeter, cataloged under National Stock Number 6625-00-899-3652, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6625-00-899-3652
Item NameVoltmeter
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
StatusACTIVE
Mounting Facility Type and Quantity3 UNTHREADED HOLE(S)
Meter Body Diameter Behind Mounting Flange2.800 INCHES MAXIMUM IN
FSC Application DataTEST SET ELECTRONIC
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleTHREE HOLE/STUD BOLT CIRCLE
Circuit Attachment Method and Quantity2 THREADED STUD AND 2 SOLDER LUG
Meter Depth Behind Mounting Flange2.450 INCHES MAXIMUM IN
Circuit Current for Which DesignedDC
Scale Selection MethodSWITCH
Movement TypeMOVING IRON VANE
Accuracy in Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
Overall Diameter3.510 INCHES MAXIMUM IN
Power SourceEXTERNAL
Style DesignatorROUND FLUSH MTG
Mounting Hole Diameter0.143 INCHES MINIMUM AND 0.157 INCHES MAXIMUM IN
Specification/standard Data81349-MIL-M-10304/11 GOVERNMENT SPECIFICATION
Scale Division Quantity30 SINGLE INDICATOR SINGLE RANGE
Movement Suspension MethodTAUT BAND
Mounting Bolt Circle Diameter3.160 INCHES NOMINAL IN
ColorUNABLE TO DECODE
Pointer ColorWHITE SINGLE INDICATOR SINGLE RANGE
Test Data Document81349-MIL-M-10304 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Dial Scale Marking ColorWHITE SINGLE INDICATOR SINGLE RANGE
MaterialSTEEL
Sensitivity Rating1000.0 OHMS PER VOLT
Scale Graduation TypeLINEAR SINGLE INDICATOR SINGLE RANGE
Measurement Range+0.0 TO 30.0 VOLTS, DC SINGLE INDICATOR SINGLE RANGE
Nuclear Hardness Critical FeatureNONHARDENED
Installation DesignPANEL
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Shelf Life Code0
Criticality CodeX
Unit of IssueEA
Acquisition advice codeJN
Weight0.9500 lbs
Cube0.0450 cu ft
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MR36B030DCVVR 2/2 Government specification standardization
U.S. Government activity
MIL-M-10304/11 5/9 Secondary reference
U.S. Government activity
MIL-PRF-10304/11 4/1 Identification reference
U.S. Government activity

Frequently Asked Questions

What is NSN 6625-00-899-3652?

NSN 6625-00-899-3652 is a Voltmeter, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What are the specifications of 6625-00-899-3652?

Key specifications for 6625-00-899-3652: Mounting Facility Type and Quantity: 3 UNTHREADED HOLE(S); Meter Body Diameter Behind Mounting Flange: 2.800 INCHES MAXIMUM IN; FSC Application Data: TEST SET ELECTRONIC; Indicator Type: DIAL W/POINTER. 29 specifications are documented in the U.S. Government catalog.

Is NSN 6625-00-899-3652 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com