PartsTable TECHNICAL DATA SHEET
NSN 6625-00-809-0475Government record, cited

Ammeter6625-00-809-0475

NSN 6625-00-809-0475 · NIIN 008090475
FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment
Government record, cited
Also searched as  6625-00-809-0475 · 6625008090475 · NIIN 008090475 · 00-809-0475 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · 475391 · M125S
Nearby stock numbers  ·
Features
  • Ammeter — FSC 6625
  • Circuit Construction Type: NONELECTRONIC
  • Mounting Facility Type and Quantity: 3 THREADED STUD(S)
  • Meter Body Diameter Behind Mounting Flange: 2.210 INCHES NOMINAL IN
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: THREE HOLE/STUD BOLT CIRCLE
  • Circuit Attachment Method and Quantity: 2 THREADED STUD
  • Meter Depth Behind Mounting Flange: 1.810 INCHES NOMINAL IN
Identification
  • NSN: 6625-00-809-0475
  • NIIN: 008090475
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
General Description

The Ammeter, cataloged under National Stock Number 6625-00-809-0475, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6625-00-809-0475
Item NameAmmeter
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
StatusACTIVE
Circuit Construction TypeNONELECTRONIC
Mounting Facility Type and Quantity3 THREADED STUD(S)
Meter Body Diameter Behind Mounting Flange2.210 INCHES NOMINAL IN
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleTHREE HOLE/STUD BOLT CIRCLE
Circuit Attachment Method and Quantity2 THREADED STUD
Meter Depth Behind Mounting Flange1.810 INCHES NOMINAL IN
Circuit Current for Which DesignedDC
Scale Selection MethodTERMINAL
Movement TypeMOVING COIL, PERMANENT MAGNET
Accuracy in Percent-3.0 TO 3.0 AT FULL SCALE SINGLE INDICATOR ALL RANGES
Overall Diameter2.695 INCHES NOMINAL IN
Mounting Stud Diameter0.112 INCHES NOMINAL IN
Panel for Which DesignedNONMAGNETIC
Dielectric Withstanding Voltage in Volts2000.0
Power SourceEXTERNAL
Style DesignatorROUND FLUSH MTG
Scale Division Quantity30 SINGLE INDICATOR ALL RANGES
Movement Suspension MethodJEWEL PIVOT BASE
Mounting Bolt Circle Diameter2.440 INCHES NOMINAL IN
ColorUNABLE TO DECODE
Pointer ColorBLACK SINGLE INDICATOR ALL RANGES
Environmental ProtectionDUST RESISTANT
Mounting Stud Length0.500 INCHES NOMINAL IN
Dial Scale Marking ColorWHITE SINGLE INDICATOR ALL RANGES
MaterialPLASTIC
Sensitivity Rating66.0 MILLIVOLTS
Scale Graduation TypeLINEAR SINGLE INDICATOR ALL RANGES
Measurement Range+0.0 TO 15.0 MILLIAMPERES, DC SINGLE INDICATOR SECOND RANGE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5305-00-960-5095475391 POSSIBLE MATCH
SETSCREW
Possible match (shared part number)Rtx Corporation Dba Pratt & Whitney Div Pratt &whitney
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
475391 3/9 Design control — primary reference
U.S. Government activity
M125S 5/9 Secondary reference
Simpson Electric Company, Inc.
Related Parts
5305-00-960-5095POSSIBLE MATCH
SETSCREW
475391

Frequently Asked Questions

What is NSN 6625-00-809-0475?

NSN 6625-00-809-0475 is a Ammeter, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What NSN replaces 6625-00-809-0475?

1 possible match (shared part number, not a government interchangeability claim): 5305-00-960-5095. Verify interchangeability with system specifications before substitution.

What are the specifications of 6625-00-809-0475?

Key specifications for 6625-00-809-0475: Circuit Construction Type: NONELECTRONIC; Mounting Facility Type and Quantity: 3 THREADED STUD(S); Meter Body Diameter Behind Mounting Flange: 2.210 INCHES NOMINAL IN; Indicator Type: DIAL W/POINTER. 29 specifications are documented in the U.S. Government catalog.

Is NSN 6625-00-809-0475 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.