PartsTable TECHNICAL DATA SHEET
NSN 6625-00-581-2076Government record, cited

Meter, Special Scale6625-00-581-2076

NSN 6625-00-581-2076 · NIIN 005812076 · Part number 463-656
Hickok Waekon Llc · FSC 6625 — Electrical and Electronic Properties Measuring and Testing Instruments · FSG 66 — Instruments and Laboratory Equipment · CAGE 28569
Government record, cited
NSN 6625-00-581-2076 — this item is cataloged by the U.S. Government under National Stock Number 6625-00-581-2076. Manufacturer of record part number: 463-656.
Also searched as  6625-00-581-2076 · 6625005812076 · NIIN 005812076 · 00-581-2076 · FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments · CAGE 28569 · 463-656 · 331C111H01 · 462-015 · 178311
Nearby stock numbers  ·
Features
  • Meter,special Scale — FSC 6625
  • Mounting Facility Type and Quantity: 3 SCREW AND 3 UNTHREADED HOLE(S)
  • Meter Body Diameter Behind Mounting Flange: 2.800 INCHES MAXIMUM IN
  • FSC Application Data: TEST SET,ELECT. EQUIP.
  • Indicator Type: DIAL W/POINTER
  • Mounting Arrangement Style: THREE HOLE/STUD BOLT CIRCLE
  • Circuit Attachment Method and Quantity: 2 SCREW AND 2 SOLDER LUG
  • Meter Depth Behind Mounting Flange: 1.600 INCHES MAXIMUM IN
Identification
  • NSN: 6625-00-581-2076
  • NIIN: 005812076
  • FSC: 6625 — Electrical and Electronic Properties Measuring and Testing Instruments
  • FSG: 66 — Instruments and Laboratory Equipment
  • Primary part number: 463-656
  • Manufacturer: Hickok Waekon Llc
General Description

The Meter,special Scale, cataloged under National Stock Number 6625-00-581-2076, is classified within Federal Supply Class 6625 (Electrical and Electronic Properties Measuring and Testing Instruments) of the Instruments and Laboratory Equipment group. The manufacturer of record is Hickok Waekon Llc. Government technical data includes 28 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6625-00-581-2076
Primary Part Number463-656
Item NameMeter,special Scale
FSC / FSG6625 / 66 — Electrical and Electronic Properties Measuring and Testing Instruments
ManufacturerHickok Waekon Llc
StatusACTIVE
Mounting Facility Type and Quantity3 SCREW AND 3 UNTHREADED HOLE(S)
Meter Body Diameter Behind Mounting Flange2.800 INCHES MAXIMUM IN
FSC Application DataTEST SET,ELECT. EQUIP.
Indicator TypeDIAL W/POINTER
Mounting Arrangement StyleTHREE HOLE/STUD BOLT CIRCLE
Circuit Attachment Method and Quantity2 SCREW AND 2 SOLDER LUG
Meter Depth Behind Mounting Flange1.600 INCHES MAXIMUM IN
Circuit Current for Which DesignedDC
Movement TypeMOVING COIL, PERMANENT MAGNET
Accuracy in Percent-2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
Overall Diameter3.500 INCHES MAXIMUM IN
Special Test FeaturesCOMPLIES WITH MIL-M-10304
Panel for Which DesignedMAGNETIC
Dielectric Withstanding Voltage in Volts3000.0
Style DesignatorROUND FLUSH MTG
Mounting Hole Diameter0.150 INCHES NOMINAL IN
Features ProvidedZERO ADJUSTER
Movement Suspension MethodJEWEL PIVOT BASE
Mounting Bolt Circle Diameter3.160 INCHES NOMINAL IN
ColorUNABLE TO DECODE
Pointer ColorBLACK SINGLE INDICATOR SINGLE RANGE
Surface TreatmentPAINT
Environmental ProtectionAIRTIGHT AND DUST RESISTANT AND FUNGUS RESISTANT AND HEAT RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND WATER RESISTANT
Unable to DecodeUNABLE TO DECODE
Dial Scale Marking ColorBLACK SINGLE INDICATOR SINGLE RANGE
Special MarkingsBAD ABOVE LEFT SIDE OF SCALE; GOOD ABOVE RIGHT SIDE OF SCALE; SET ABOVE TRIANGULAR AREA IN CENTER OF SCALE
MaterialSTEEL
Sensitivity Rating100.0 MICROAMPERES
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5365-00-591-7981178311 POSSIBLE MATCH
RING,BALL VALVE STE
Possible match (shared part number)Tyco Fire Products Lp
5331-01-112-7766462015 POSSIBLE MATCH
O-RING
Possible match (shared part number)Ramsey Winch Co
2530-01-273-1125178-311 POSSIBLE MATCH
BRAKE BOOSTER ASSEMBLY,MASTER CY
Possible match (shared part number)General Motors Llc Dba General Motors Llc
Cross-Reference Index
Part NumberManufacturer
463-656 Hickok Waekon Llc (USA)
Reference documents
ReferenceMeaning
331C111H01 3/2 Design control — primary reference
U.S. Government activity
462-015 5/9 Secondary reference
Hickok Waekon Llc
178311 5/9 Secondary reference
Solartron Electronics Inc Weston Instruments Div
Related Parts
5365-00-591-7981POSSIBLE MATCH
RING,BALL VALVE STE
178311
5331-01-112-7766POSSIBLE MATCH
O-RING
462015
2530-01-273-1125POSSIBLE MATCH
BRAKE BOOSTER ASSEMBLY,MASTER CY
178-311

Frequently Asked Questions

What is NSN 6625-00-581-2076?

NSN 6625-00-581-2076 is a Meter,special Scale, manufactured by Hickok Waekon Llc, classified under FSC 6625, Electrical and Electronic Properties Measuring and Testing Instruments. Status: active.

What part numbers are listed for NSN 6625-00-581-2076?

NSN 6625-00-581-2076 has 1 manufacturer part number on file: 463-656 (Hickok Waekon Llc).

What NSN replaces 6625-00-581-2076?

3 possible matches (shared part number, not a government interchangeability claim): 5365-00-591-7981, 5331-01-112-7766, 2530-01-273-1125. Verify interchangeability with system specifications before substitution.

What are the specifications of 463-656?

Key specifications for 463-656: Mounting Facility Type and Quantity: 3 SCREW AND 3 UNTHREADED HOLE(S); Meter Body Diameter Behind Mounting Flange: 2.800 INCHES MAXIMUM IN; FSC Application Data: TEST SET,ELECT. EQUIP.; Indicator Type: DIAL W/POINTER. 28 specifications are documented in the U.S. Government catalog.

Is NSN 6625-00-581-2076 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com