The Control Set,coronavirus, cataloged under National Stock Number 6550-01-727-7892, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Biofire Diagnostics Llc. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: BX.
| Parameter | Value |
|---|---|
| NSN | 6550-01-727-7892 |
| Primary Part Number | 424062 |
| Item Name | Control Set,coronavirus |
| FSC / FSG | 6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets |
| Manufacturer | Biofire Diagnostics Llc |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | BX |
| Part Number | Manufacturer |
|---|---|
| 424062 PRIMARY | Biofire Diagnostics Llc (USA) |
| 424062 | Show Me Quality Consulting, Llc (USA) |
| Reference | Meaning |
|---|---|
| 6550NCM251317 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1682740 | 5/1 Secondary reference U.S. Government activity |
NSN 6550-01-727-7892 is a Control Set,coronavirus, manufactured by Biofire Diagnostics Llc, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.
NSN 6550-01-727-7892 has 2 manufacturer part numbers on file: 424062 (Biofire Diagnostics Llc), 424062 (Show Me Quality Consulting, Llc).
Key specifications for 424062: Special Features: KIT TEST IS AN OPTIONAL SURROGATE EXTERNAL ASSAYED QUALITY CONTROL FOR MONITORING PERFORMANCE OF IN VITRO LABORATORY NUCLEIC ACID TESTING PROCEDURES USING THE QUALITATIVE BIOFIRE COVID 19 TEST ON FILMARRAY AND FILMARRAY 2.0 TORCH SYSTEMS; STORE AT ROOM TEMPERATURE (15C TO 30C). DO NOT REFRIGERATE; AVOID STORAGE OF ANY MATERIALS NEAR HEATING OR COOLING VENTS, OR IN DIRECT SUNLIGHT; FOR USE UNDER AN EMERGENCY USE AUTHORIZATION (EUA) ONLY; BOX OF 6; INCLUDES: INDIVIDUALLY PACKAGED BIOFIRE SHIELD POSITIVE EXTERNAL CONTROL VIALS FOR THE BIOFIRE COVID-19 TEST, INSTRUCTIONS AND DOCUMENTS.; Part Name Assigned by Controlling Agency: COVID-19 CONTROL SET, 6 POSITIVE EXTERNAL CONTROL VIALS. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.