PartsTable TECHNICAL DATA SHEET
NSN 6550-01-695-0333Government record, cited

Guard Column6550-01-695-0333

NSN 6550-01-695-0333 · NIIN 016950333 · Part number 0350624560017
Indra Australia Pty Limited · FSC 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE Z0MD7
Government record, cited
NSN 6550-01-695-0333 — this item is cataloged by the U.S. Government under National Stock Number 6550-01-695-0333. Manufacturer of record part number: 0350624560017.
Also searched as  6550-01-695-0333 · 6550016950333 · NIIN 016950333 · 01-695-0333 · FSC 6550 In Vitro Diagnostic Substances, Reagents, Test Kits and Sets · CAGE Z0MD7 · 0350624560017 · 088583
Nearby stock numbers  ·
Features
  • Guard Column — FSC 6550
  • Overall Diameter: 2.0 MILLIMETERS NOMINAL MM
  • 1 manufacturer part number on file
  • Manufacturer of record: Indra Australia Pty Limited
Identification
  • NSN: 6550-01-695-0333
  • NIIN: 016950333
  • FSC: 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 0350624560017
  • Manufacturer: Indra Australia Pty Limited
General Description

The Guard Column, cataloged under National Stock Number 6550-01-695-0333, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Indra Australia Pty Limited. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6550-01-695-0333
Primary Part Number0350624560017
Item NameGuard Column
FSC / FSG6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
ManufacturerIndra Australia Pty Limited
StatusACTIVE
Overall Diameter2.0 MILLIMETERS NOMINAL MM
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
0350624560017 Indra Australia Pty Limited (AUS)
Reference documents
ReferenceMeaning
088583 3/9 Design control — primary reference
Thermo Fisher Scientific Inc.
No interchangeability data on file.
Other items in FSC 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6550-00-022-8191
6550-00-022-8191 · Item name not on file
6550-00-037-2028
6550-00-037-2028 · Item name not on file
6550-00-063-6073
6550-00-063-6073 · Item name not on file
6550-00-067-4539
6550-00-067-4539 · Item name not on file
6550-00-071-0610
TEST STRIPS AND COLOR CHART,KETO
6550-00-080-0617
6550-00-080-0617 · Item name not on file
6550-00-093-4228
6550-00-093-4228 · Item name not on file
6550-00-093-4648
6550-00-093-4648 · Item name not on file

Frequently Asked Questions

What is NSN 6550-01-695-0333?

NSN 6550-01-695-0333 is a Guard Column, manufactured by Indra Australia Pty Limited, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.

What part numbers are listed for NSN 6550-01-695-0333?

NSN 6550-01-695-0333 has 1 manufacturer part number on file: 0350624560017 (Indra Australia Pty Limited).

What are the specifications of 0350624560017?

Key specifications for 0350624560017: Overall Diameter: 2.0 MILLIMETERS NOMINAL MM; Overall Length: 50.0 MILLIMETERS NOMINAL MM; Special Features: 270 UEQ COLUMN CAPACITY; 0.16 TO 0.25 ML/MIN FLOW RATE; Part Name Assigned by Controlling Agency: IC COLUMN. 1 specification is documented in the U.S. Government catalog.

Is NSN 6550-01-695-0333 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com