The Control,blood Chemistry, cataloged under National Stock Number 6550-01-693-9936, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Abbott Laboratories Inc. Div Abbott Point of Care. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: BX.
| Parameter | Value |
|---|---|
| NSN | 6550-01-693-9936 |
| Primary Part Number | 06P17-25 |
| Item Name | Control,blood Chemistry |
| FSC / FSG | 6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets |
| Manufacturer | Abbott Laboratories Inc. Div Abbott Point of Care |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | BX |
| Part Number | Manufacturer |
|---|---|
| 06P17-25 PRIMARY | Abbott Laboratories Inc. Div Abbott Point of Care (USA) |
| Reference | Meaning |
|---|---|
| 1590657 | 5/1 Secondary reference U.S. Government activity |
| 6550NCM216942 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6550-01-693-9936 is a Control,blood Chemistry, manufactured by Abbott Laboratories Inc. Div Abbott Point of Care, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.
NSN 6550-01-693-9936 has 1 manufacturer part number on file: 06P17-25 (Abbott Laboratories Inc. Div Abbott Point of Care).
Key specifications for 06P17-25: Special Features: FOR USE WITH THE I-STAT TBI PLASMA CARTRIDGE (P/N 04X64-25) ON THE I-STAT ALINITY BLOOD ANALYZER. AQUEOUS CONTROL LEVEL 1 FOR MONITORING THE PERFORMANCE OF GLIAL FIBRILLARY ACIDIC PROTEIN (GFAP) AND UBIQUITIN CARBOXYL-TERMINAL HYDROLASE L1 (UCH-L1) ASSAYS ON THE I-STAT TBI PLASMA CARTRIDGE WITH THE 1-STAT ALINITY INSTRUMENT. MUST BE KEPT FROZEN AT -20 C (-4 F) UNTIL THE EXPIRATION DATE; DO NOT USE BEYOND THE EXPIRATION DATE; ONE BOX CONTAINS 6 VIALS; EAEACH VIAL CONTAINS 1 ML OF FROZEN SERUM.; Part Name Assigned by Controlling Agency: I-STAT TBI CONTROL LEVEL 1, 6S. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.