PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

31124Test Kit,hepatitis B Surface Ant

Biomerieux Inc · NSN 6550-01-658-8877 · FSC 6550 · No Item Name Available
Verified by PartsTable
NSN 6550-01-658-8877 — this item is cataloged by the U.S. Government under National Stock Number 6550-01-658-8877. Primary manufacturer part number: 31124.
Features
  • Test Kit,hepatitis B Surface Ant — FSC 6550
  • Test Capability Quantity: 25
  • Test Media: BLOOD OR SERUM
  • Protective Storage Feature: SUBJECT TO DAMAGE BY FREEZING
  • Component Breakdown Within Each Test Kit: 25 SEALED POUCHES EACH CONTAINING 1 TEST CASSETTE, 1 PIPETTE, 1 DESICCANT; AND 1 BUFFER DROPPER BOTTLE
  • 4 verified cross-references
  • Primary manufacturer: Biomerieux Inc
Applications
  • Industrial maintenance and repair
  • Government and military logistics
  • Equipment overhaul and refurbishment
General Description

The Test Kit,hepatitis B Surface Ant, cataloged under National Stock Number 6550-01-658-8877, is classified within Federal Supply Class 6550 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Biomerieux Inc. Government technical data includes 4 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 10 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: KT.

Technical Specifications
ParameterValue
NSN6550-01-658-8877
Primary Part Number31124
Item NameTest Kit,hepatitis B Surface Ant
FSC / FSG6550 / 65 — No Item Name Available
ManufacturerBiomerieux Inc
StatusACTIVE
Test Capability Quantity25
Test MediaBLOOD OR SERUM
Protective Storage FeatureSUBJECT TO DAMAGE BY FREEZING
Component Breakdown Within Each Test Kit25 SEALED POUCHES EACH CONTAINING 1 TEST CASSETTE, 1 PIPETTE, 1 DESICCANT; AND 1 BUFFER DROPPER BOTTLE
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Unit of IssueKT
Verified Substitutes 10
5315-00-008-5833 INTERCHANGEABLE
Pin,grooved,headless
3455-00-228-5228 INTERCHANGEABLE
Cutter,milling,end
4720-00-775-93203-1124 INTERCHANGEABLE
Tubing,nonmetallic
Arrowhead Products Corp
5330-00-816-1138 INTERCHANGEABLE
Gasket
3020-00-858-0511 INTERCHANGEABLE
Gear,spur
5305-01-145-853131124 INTERCHANGEABLE
Screw,machine
Barnes Group Inc. Dba Barnes Distribution
6150-01-373-26811430118 INTERCHANGEABLE
Cable Assembly,special Purpose,e
Lexmark International, Inc. Dba Lexmark
6515-01-419-1428311.24 INTERCHANGEABLE
Tap,bone Screw
Synthes Usa Lp Div Synthes Maxillo Facial Division Dba Synthes Maxillo Facial Division
6515-01-611-0818489278 INTERCHANGEABLE
Needle,nerve Block
B. Braun Medical Inc
5340-01-612-4136 INTERCHANGEABLE
Handle,manual Control
Cross-Reference Index
Part NumberManufacturer
31124 PRIMARY Biomerieux Inc (USA)
1430118 Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia (USA)
6550NCM163164 Defense Medical Standardization Board (USA)
VIKIA HBS AG Biomerieux Inc (USA)
Related Parts
5315-00-008-5833INTERCHANGEABLE
PIN,GROOVED,HEADLESS
3455-00-228-5228INTERCHANGEABLE
CUTTER,MILLING,END
4720-00-775-9320INTERCHANGEABLE
TUBING,NONMETALLIC
3-1124
5330-00-816-1138INTERCHANGEABLE
GASKET
3020-00-858-0511INTERCHANGEABLE
GEAR,SPUR
5305-01-145-8531INTERCHANGEABLE
SCREW,MACHINE
31124
6150-01-373-2681INTERCHANGEABLE
CABLE ASSEMBLY,SPECIAL PURPOSE,E
1430118
6515-01-419-1428INTERCHANGEABLE
TAP,BONE SCREW
311.24
6515-01-611-0818INTERCHANGEABLE
NEEDLE,NERVE BLOCK
489278
5340-01-612-4136INTERCHANGEABLE
HANDLE,MANUAL CONTROL

Frequently Asked Questions

What is NSN 6550-01-658-8877?

NSN 6550-01-658-8877 is a Test Kit,hepatitis B Surface Ant, manufactured by Biomerieux Inc, classified under FSC 6550 (No Item Name Available). Status: active.

What are the part numbers for NSN 6550-01-658-8877?

NSN 6550-01-658-8877 has 4 cross-referenced part numbers: 31124 (Biomerieux Inc), 1430118 (Defense Logistics Agency Directorate of Medical Materiel Defense Supply Center Philadelphia), 6550NCM163164 (Defense Medical Standardization Board), VIKIA HBS AG (Biomerieux Inc).

What NSN replaces 6550-01-658-8877?

There are 10 known substitutes for 6550-01-658-8877: 5315-00-008-5833, 3455-00-228-5228, 4720-00-775-9320 and 7 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 31124?

Key specifications for 31124: Special Features: HBS AG RAPID ULTRA HEPATITIS B SURFACE ANTIGEN TEST DEVICE; EACH KIT INCLUDES: 25 SEALED POUCHES EACH CONTAINING 1 TEST CASSETTE, 1 PIPETTE, 1 DESICANT; AND 1 BUFFER DROPPER BOTTLE FOR WHOLE BLOOD SAMPLES; CE-MARKED; FIRST RESULTS IN 15 MINUTES; SAMPLE VOLUME WHOLE BLOOD 75 MICROLITERS, SERUM OR PLASMA; STORAGE TEMPERATURE 4 TO 30 DEGREES C; DO NOT FREEZE; 25 TESTS. PROCURE AT UNIT LEVEL WITH GCC.; Test Capability Quantity: 25; Test Media: BLOOD OR SERUM; Protective Storage Feature: SUBJECT TO DAMAGE BY FREEZING. 6 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com