The Test Kit,e Coli Detection, cataloged under National Stock Number 6550-01-625-5025, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Meridian Bioscience Inc. Government technical data includes 6 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6550-01-625-5025 |
| Primary Part Number | 751630 |
| Item Name | Test Kit,e Coli Detection |
| FSC / FSG | 6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets |
| Manufacturer | Meridian Bioscience Inc |
| Status | ACTIVE |
| Protective Storage Feature | REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C DEGC |
| Test Media | FECES |
| Test Capability Quantity | 30 |
| Usage Design | E. COLI TESTING |
| Component Breakdown Within Each Test Kit | E. COLI SHIGA TOXINS 1 AND 2 |
| Total Primary Container Quantity | 30 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 751630 | Meridian Bioscience Europe (FRA) |
| 751630 PRIMARY | Meridian Bioscience Inc (USA) |
| Reference | Meaning |
|---|---|
| 6550NCM173726 | 5/1 Secondary reference Defense Medical Standardization Board |
| 1484771 | 5/1 Secondary reference U.S. Government activity |
| 23-043-200 | 5/9 Secondary reference Fisher Scientific Company L.l.c. |
NSN 6550-01-625-5025 is a Test Kit,e Coli Detection, manufactured by Meridian Bioscience Inc, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.
NSN 6550-01-625-5025 has 2 manufacturer part numbers on file: 751630 (Meridian Bioscience Europe), 751630 (Meridian Bioscience Inc).
Key specifications for 751630: Protective Storage Feature: REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C DEGC; Special Features: IMMUNOCARD STAT EHEC; THE NEW STANDARD OF CARE IN RAPID E. COLI TESTING: DETECTS ALL SHIGA TOXIN-PRODUCING E. COLI AND DIFFERENTIATES BETWEEN TOXINS 1 AND 2 FOR OPTIMAL PATIENT MANAGEMENT WHILE COMPLYING WITH CDC RECOMMENDATIONS: AN IMMUNOCHROMATOGRPHIC RAPID TEST FOR THE QUALITATIVE DETECTION OF SHIGA TOXINS 1 AND 2 PRODUCED BY E. COLI IN CULTURES DERIVED FROM CLINICAL STOOL SPECIMENS; SENSITIVITY: MAC BROTH: 93.8%, GN BROTH: 89.1%, SMAC PLATE: 100%; SPECIFICITY: MAC BROTH: 99.7%, GN BROTH: 99.7%, SMAC PLATE: 99.6%; INCLUDES 30 TEST DEVICES, SAMPLE DILUENT/NEGATIVE CONTROL IN A PLSTIC DROPPER VIAL, POSITIVE CONTROL IN A PLASTIC DROPPER VIAL, AND 150 UL DISPOSABLE PLASTIC; Test Media: FECES; Test Capability Quantity: 30. 6 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.