The Control Kit,positive,malaria, cataloged under National Stock Number 6550-01-599-9065, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Abbott Rapid Dx North America Llc Dba Alere North America Llc. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: PG.
| Parameter | Value |
|---|---|
| NSN | 6550-01-599-9065 |
| Primary Part Number | 665-010 |
| Item Name | Control Kit,positive,malaria |
| FSC / FSG | 6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets |
| Manufacturer | Abbott Rapid Dx North America Llc Dba Alere North America Llc |
| Status | ACTIVE |
| Storage Temp Range | +2.0 TO 8.0 CELSIUS DEGC |
| Functional Description | INTENDED FOR USE AS AN ASSAYED POSITIVE EXTERNAL QUALITY CONTROL WITH THE QUALITATIVE BINAXNOW MALARIA TEST; DESIGNED FOR ROUTINE USE TO AID IN VERIFYING PROPER PERFORMANCE OF THE PROCEDURE AND THE ANTIGEN DETECTION REAGENTS OF THE BINAXNOW MALARIA TEST |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Unit of Issue | PG |
| Part Number | Manufacturer |
|---|---|
| 665-010 PRIMARY | Abbott Rapid Dx North America Llc Dba Alere North America Llc (USA) |
| Reference | Meaning |
|---|---|
| 27049 | 5/1 Secondary reference U.S. Government activity |
| 6550NCM116890 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6550-01-599-9065 is a Control Kit,positive,malaria, manufactured by Abbott Rapid Dx North America Llc Dba Alere North America Llc, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.
NSN 6550-01-599-9065 has 1 manufacturer part number on file: 665-010 (Abbott Rapid Dx North America Llc Dba Alere North America Llc).
Key specifications for 665-010: Storage Temp Range: +2.0 TO 8.0 CELSIUS DEGC; Special Features: RECOMBINANT ANTIGEN CONTROL CONTAINING A MIXTURE OF PLASMODIUM FALCIPARUM HISTIDINE-RICH PROTEIN II AND PANMALARIA PROTEIN; CAN BE USED AS A QUALITY CONTROL SAMPLE REPRESENTATIVE OF A POSITIVE TEST RESULT AND TO VERIFY PROPER PERFORMANCE OF THE PROCEDURE AND REAGENTS OF THE BINAXNOW MALARIA TEST; Functional Description: INTENDED FOR USE AS AN ASSAYED POSITIVE EXTERNAL QUALITY CONTROL WITH THE QUALITATIVE BINAXNOW MALARIA TEST; DESIGNED FOR ROUTINE USE TO AID IN VERIFYING PROPER PERFORMANCE OF THE PROCEDURE AND THE ANTIGEN DETECTION REAGENTS OF THE BINAXNOW MALARIA TEST; Part Name Assigned by Controlling Agency: CONTROL KIT POSITIVE MALARIA BINAXNOW. 2 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.