PartsTable TECHNICAL DATA SHEET
NSN 6550-01-542-3789Government record, cited

Reagent Set, Blood Grouping Test6550-01-542-3789

NSN 6550-01-542-3789 · NIIN 015423789 · Part number 349202
Becton, Dickinson and Company · FSC 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0GKS0
Government record, cited
NSN 6550-01-542-3789 — this item is cataloged by the U.S. Government under National Stock Number 6550-01-542-3789. Manufacturer of record part number: 349202.
Also searched as  6550-01-542-3789 · 6550015423789 · NIIN 015423789 · 01-542-3789 · FSC 6550 In Vitro Diagnostic Substances, Reagents, Test Kits and Sets · CAGE 0GKS0 · 349202
Nearby stock numbers  ·
Features
  • Reagent Set,blood Grouping Test — FSC 6550
  • 2 manufacturer part numbers on file
  • Manufacturer of record: Becton, Dickinson and Company
Identification
  • NSN: 6550-01-542-3789
  • NIIN: 015423789
  • FSC: 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 349202
  • Manufacturer: Becton, Dickinson and Company
General Description

The Reagent Set,blood Grouping Test, cataloged under National Stock Number 6550-01-542-3789, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Becton, Dickinson and Company. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6550-01-542-3789
Primary Part Number349202
Item NameReagent Set,blood Grouping Test
FSC / FSG6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
ManufacturerBecton, Dickinson and Company
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
349202 Becton Dickinson Benelux Nv (BEL)
349202 PRIMARY Becton, Dickinson and Company (USA)
No interchangeability data on file.
Other items in FSC 6550 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6550-00-022-8191
6550-00-022-8191 · Item name not on file
6550-00-037-2028
6550-00-037-2028 · Item name not on file
6550-00-063-6073
6550-00-063-6073 · Item name not on file
6550-00-067-4539
6550-00-067-4539 · Item name not on file
6550-00-071-0610
TEST STRIPS AND COLOR CHART,KETO
6550-00-080-0617
6550-00-080-0617 · Item name not on file
6550-00-093-4228
6550-00-093-4228 · Item name not on file
6550-00-093-4648
6550-00-093-4648 · Item name not on file

Frequently Asked Questions

What is NSN 6550-01-542-3789?

NSN 6550-01-542-3789 is a Reagent Set,blood Grouping Test, manufactured by Becton, Dickinson and Company, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.

What part numbers are listed for NSN 6550-01-542-3789?

NSN 6550-01-542-3789 has 2 manufacturer part numbers on file: 349202 (Becton Dickinson Benelux Nv), 349202 (Becton, Dickinson and Company).

What are the specifications of 349202?

Key specifications for 349202: Special Features: BD FACS LYSING SOLUTION IS INTENDED FOR LYSING RED BLOOD CELLS FOLLOWING DIRECT IMMUNOFLUORESCENCE STAINING OF HUMAN PERIPHERAL BLOOD CELLS WITH MONOCLONAL ANTIBODIES PRIOR TO FLOW CYTOMETRIC ANALYSIS;FACS LYSING SOLUTION IS APPROPRIATE FOR USE WITH REAGENTS SUCH AS BD TRITEST OR SIMULTEST REAGENTS AND A SUITABLY EQUIPPED FLOW CYTOMETER;IT MAY BE USE IN BOTH LYSE/WASH AND LYSE/NO-WASH PROCEDURES;FACS LYSING SOLUTION, 10X CONCENTRATE, IS PROVIDED AS 100 ML OF A PROPRIETARY BUFFERED SOLUTION CONTAINING <15% FORMALDEHYDE AND <50% DIETHYLENE GLYCOL;THIS QUANTITY IS SUFFICIENT FOR 2000 TESTS WHEN USED IN BD LYSE/NO-WASH PROCEDURES (EG,TRITEST), AND FOR 500 TESTS WHEN USED IN LYSE/WASH PROCEDURES (EG, SIMULTEST); Part Name Assigned by Controlling Agency: FACS LYSING SOLUTION. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6550-01-542-3789 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com