The Test Kit,cytomegalovirus Antibod, cataloged under National Stock Number 6550-01-476-8220, is classified within Federal Supply Class 6550 (In Vitro Diagnostic Substances, Reagents, Test Kits and Sets) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 3 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6550-01-476-8220 |
| Item Name | Test Kit,cytomegalovirus Antibod |
| FSC / FSG | 6550 / 65 — In Vitro Diagnostic Substances, Reagents, Test Kits and Sets |
| Status | ACTIVE |
| Test Capability Quantity | 96 |
| Usage Design | MEASURES TOTAL CYTOKINO (FREE ANDBOUND) REGARDLESS OF CYTOKINE BINDING MOLECULES |
| Component Breakdown Within Each Test Kit | RECOMBINANT HUMAN IL-7 STANDARD, RABBIT ANTI-HUMAN IL-7 POLYCIONAL ANTIBODY, BIOTIN CONJUGATED IL-7, 96-WELL PRE-COATED IMMUNOPLATE, (GOAT ANTI-RABBIT ANTIBODY), ASSAY DILUENT, SERUM DILUENT, WASH BUFFER, STREPTAVIDIN CONJUGATED ALKALINE PHOSPHATASE, COLOR REAGENT A, COLOR REAGENT B, STOP SOLUTION, ACETATE PLATE SEALERS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AC-160 | 3/9 Design control — primary reference Cytimmune Sciences, Inc. |
| IL-7 | 5/9 Secondary reference Cytimmune Sciences, Inc. |
NSN 6550-01-476-8220 is a Test Kit,cytomegalovirus Antibod, classified under FSC 6550, In Vitro Diagnostic Substances, Reagents, Test Kits and Sets. Status: active.
Key specifications for 6550-01-476-8220: Special Features: STORAGE TEMPERATURE 4 DEG C; ASSAY TEMPERATURE ROOM TEMPERATURE; SAMPLEMATRIX SERUM, PLASMA, CSF, SALIVA, OTHER BIOLOGICAL FLUIDS, AND TISSUE CULTURE MEDIA DEGC; Test Capability Quantity: 96; Part Name Assigned by Controlling Agency: HUMAN IL-7; Usage Design: MEASURES TOTAL CYTOKINO (FREE ANDBOUND) REGARDLESS OF CYTOKINE BINDING MOLECULES. 3 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.