The Test Kit,dna Autoantibody Determ, cataloged under National Stock Number 6550-01-243-0513, is classified within Federal Supply Class 6550 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group. Government technical data includes 4 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 8 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6550-01-243-0513 |
| Primary Part Number | 31069 |
| Item Name | Test Kit,dna Autoantibody Determ |
| FSC / FSG | 6550 / 65 — No Item Name Available |
| Manufacturer | Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group |
| Status | ACTIVE |
| Test Capability Quantity | 48 |
| Component Breakdown Within Each Test Kit | SIX 8 WELL SUBSTRATE SLIDES; ONE 2.5ML BT W/DROPPER OF CONJUGATE; ONE 0.5ML BT W/DROPPER OF LYOPHILIZED POSITIVE CONTROL; ONE 0.5ML BT W/DROPPER OF NEGATIVE CONTROL; ONE 2.5ML BT W/DROPPER OF MOUNTING MEDIA; ONE 2.5ML BT W/DROPPER OF EVANS BLUE COUNTER STAIN; ONE 11.34GM PACKET OF PHOSPHATE BUFFERED SALINE; 6 BLOTTING STRIPS |
| Usage Design | TESTS FOR AUTOANTIBODIES TO DNA |
| Test Media | SERUM |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| QUANTAFLUOR | Kallestad Diagnostics Inc (USA) |
| 158 | Kallestad Diagnostics Inc (USA) |
| 31069 PRIMARY | Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group (USA) |
| KALLESTAD CRITHIDIA LUCILIAE KIT | Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group (USA) |
| QUANTAFLUOR NDNA | Kallestad Diagnostics Inc (USA) |
NSN 6550-01-243-0513 is a Test Kit,dna Autoantibody Determ, manufactured by Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group, classified under FSC 6550 (No Item Name Available). Status: active.
NSN 6550-01-243-0513 has 5 cross-referenced part numbers: QUANTAFLUOR (Kallestad Diagnostics Inc), 158 (Kallestad Diagnostics Inc), 31069 (Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group), KALLESTAD CRITHIDIA LUCILIAE KIT (Bio-Rad Laboratories, Inc. Dba Bio Rad Laboratories Div Life Science Group), QUANTAFLUOR NDNA (Kallestad Diagnostics Inc).
There are 8 known substitutes for 6550-01-243-0513: 5950-00-754-9547, 5310-00-939-9092, 3455-01-084-9526 and 5 more. Verify interchangeability with system specifications before substitution.
Key specifications for 31069: Test Capability Quantity: 48; Part Name Assigned by Controlling Agency: TEST KIT DNA AUTOANTIBODY DETERMINATION SUFFICIENT FOR 48 TESTS; Component Breakdown Within Each Test Kit: SIX 8 WELL SUBSTRATE SLIDES; ONE 2.5ML BT W/DROPPER OF CONJUGATE; ONE 0.5ML BT W/DROPPER OF LYOPHILIZED POSITIVE CONTROL; ONE 0.5ML BT W/DROPPER OF NEGATIVE CONTROL; ONE 2.5ML BT W/DROPPER OF MOUNTING MEDIA; ONE 2.5ML BT W/DROPPER OF EVANS BLUE COUNTER STAIN; ONE 11.34GM PACKET OF PHOSPHATE BUFFERED SALINE; 6 BLOTTING STRIPS; Usage Design: TESTS FOR AUTOANTIBODIES TO DNA. 5 total characteristics are documented in the Federal Logistics Information System.