NSN 6550-01-217-8842 — this item is cataloged by the U.S. Government under National Stock Number 6550-01-217-8842. Primary manufacturer part number: 719510.
6550-01-217-8842 — No Item Name Available illustration
Features
Test Kit,antibody Detection,red — FSC 6550
Protective Storage Feature: REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C DEGC
Usage Design: DETECTING UNEXPECTED ANTIBODIES
Component Breakdown Within Each Test Kit: TEN 3ML VIALS RED BLOOD CELLS; ONE 2ML VIAL DILVENT; ONE 1ML VIAL POOLED CORD CELLS
3 verified cross-references
Primary manufacturer: Ortho Diagnostic Systems Inc
Applications
Industrial maintenance and repair
Government and military logistics
Equipment overhaul and refurbishment
General Description
The Test Kit,antibody Detection,red, cataloged under National Stock Number 6550-01-217-8842, is classified within Federal Supply Class 6550 (No Item Name Available) of the Medical, Dental, and Veterinary Equipment group. The primary manufacturer of record is Ortho Diagnostic Systems Inc. Government technical data includes 3 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 3 commercial cross-references from 1 manufacturer, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active. Unit of issue: EA.
Technical Specifications
Parameter
Value
NSN
6550-01-217-8842
Primary Part Number
719510
Item Name
Test Kit,antibody Detection,red
FSC / FSG
6550 / 65 — No Item Name Available
Manufacturer
Ortho Diagnostic Systems Inc
Status
ACTIVE
Protective Storage Feature
REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C DEGC
Usage Design
DETECTING UNEXPECTED ANTIBODIES
Component Breakdown Within Each Test Kit
TEN 3ML VIALS RED BLOOD CELLS; ONE 2ML VIAL DILVENT; ONE 1ML VIAL POOLED CORD CELLS
NSN 6550-01-217-8842 is a Test Kit,antibody Detection,red, manufactured by Ortho Diagnostic Systems Inc, classified under FSC 6550 (No Item Name Available). Status: active.
What are the part numbers for NSN 6550-01-217-8842?
NSN 6550-01-217-8842 has 3 cross-referenced part numbers: RESOLVE PANEL A (Ortho Diagnostic Systems Inc), 719510 (Ortho Diagnostic Systems Inc), 1951 (Ortho Diagnostic Systems Inc).
What NSN replaces 6550-01-217-8842?
There are 12 known substitutes for 6550-01-217-8842: 5310-00-214-3195, 5998-00-252-7147, 6220-00-299-5646 and 9 more. Verify interchangeability with system specifications before substitution.
What are the specifications of 719510?
Key specifications for 719510: Protective Storage Feature: REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C DEGC; Part Name Assigned by Controlling Agency: TEST KIT ANTIBODY DETECTION RED BLOOD CELLS; Usage Design: DETECTING UNEXPECTED ANTIBODIES; Component Breakdown Within Each Test Kit: TEN 3ML VIALS RED BLOOD CELLS; ONE 2ML VIAL DILVENT; ONE 1ML VIAL POOLED CORD CELLS. 4 total characteristics are documented in the Federal Logistics Information System.
✓ Validated with multiple authoritative sources, including Government, OEM, and Certified sources.