The Calibration System,ventilator, cataloged under National Stock Number 6545-01-606-1476, is classified within Federal Supply Class 6545 (Replenishable Field Medical Sets, Kits, and Outfits) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Zoll Medical Corporation Dba Zoll. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6545-01-606-1476 |
| Primary Part Number | 800-RCS1-01 |
| Item Name | Calibration System,ventilator |
| FSC / FSG | 6545 / 65 — Replenishable Field Medical Sets, Kits, and Outfits |
| Manufacturer | Zoll Medical Corporation Dba Zoll |
| Status | ACTIVE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 800-RCS1-01 PRIMARY | Zoll Medical Corporation Dba Zoll (USA) |
| Reference | Meaning |
|---|---|
| 571-RCS1-01 | 5/9 Secondary reference Impact Instrumentation Inc. Dba Impact Medical |
| 32165 | 5/1 Secondary reference U.S. Government activity |
| 6545NCM127821 | 5/1 Secondary reference Defense Medical Standardization Board |
NSN 6545-01-606-1476 is a Calibration System,ventilator, manufactured by Zoll Medical Corporation Dba Zoll, classified under FSC 6545, Replenishable Field Medical Sets, Kits, and Outfits. Status: active.
NSN 6545-01-606-1476 has 1 manufacturer part number on file: 800-RCS1-01 (Zoll Medical Corporation Dba Zoll).
Key specifications for 800-RCS1-01: Special Features: REMOTE CALIBRATION SYSTEM; INCLUDES: (1) REMOTE CALIBRATION SYSTEM 571-RCM1-01, (1) REMOTE CALIBRATION MODULE 571-RCM1-01, (1) BACTERIA FILTER 465-0030-00, (1) USB A TO MINI B CABLE 708-0059-00, (1) O2 SENSOR CABLE 708-0060-00, (1) TRANSDUCER OXYGEN SENSOR 804-0008-00, (1) O2 SENSOR THREADED TEE 820-0128-00, (1) TEST LUNG W/ 22MM ELBOW 820-0105-00, (1) VENTILATOR CIRCUIT SINGLE LIMB WYE 820-0106-00, (1) O2 "Y" TUBING ASSEMBLY W/ QUICK DISCONNECT 703-RCM1-01, (1) TUBING ASSEMBLY FUNCTIONAL TEST Y ADAPTER 703-RCM1-02, (1) CALIBRATION RESISTOR (R NO.1) 820-0129-00, (1) OXYGEN REGULATOR ASEMBLY 703-RCM1-04, (1) YOKE ADAPTER CGA 870 X CGA 540 480-0344-00, (1) FUNCTIONAL TEST RESISTOR (R NO.2) 820-0127-00, (1) LAPTOP PC (W/POWER SUPPLY) CONFIGURED FOR IMPACT RCS USE ONLY; (1) QUICK REFERENCE GUIDE 907-RCS1-01, (1) OPERATION MANUAL 906-RCS1-01, (1) TRANSIT CASE ASSEMBLY 703-RSC1-01 MM; Part Name Assigned by Controlling Agency: CALIBRATION SYSTEM 731 VENTILATOR WITH TRANSIT CASE. 0 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.