PartsTable TECHNICAL DATA SHEET
NSN 6545-01-606-1476Government record, cited

Calibration System, Ventilator6545-01-606-1476

NSN 6545-01-606-1476 · NIIN 016061476 · Part number 800-RCS1-01
Zoll Medical Corporation Dba Zoll · FSC 6545 — Replenishable Field Medical Sets, Kits, and Outfits · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 0UJ27
Government record, cited
NSN 6545-01-606-1476 — this item is cataloged by the U.S. Government under National Stock Number 6545-01-606-1476. Manufacturer of record part number: 800-RCS1-01.
Also searched as  6545-01-606-1476 · 6545016061476 · NIIN 016061476 · 01-606-1476 · FSC 6545 Replenishable Field Medical Sets, Kits, and Outfits · CAGE 0UJ27 · 800-RCS1-01 · 571-RCS1-01 · 32165 · 6545NCM127821
Nearby stock numbers  ·
Features
  • Calibration System,ventilator — FSC 6545
  • 1 manufacturer part number on file
  • Manufacturer of record: Zoll Medical Corporation Dba Zoll
Identification
  • NSN: 6545-01-606-1476
  • NIIN: 016061476
  • FSC: 6545 — Replenishable Field Medical Sets, Kits, and Outfits
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: 800-RCS1-01
  • Manufacturer: Zoll Medical Corporation Dba Zoll
General Description

The Calibration System,ventilator, cataloged under National Stock Number 6545-01-606-1476, is classified within Federal Supply Class 6545 (Replenishable Field Medical Sets, Kits, and Outfits) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Zoll Medical Corporation Dba Zoll. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN6545-01-606-1476
Primary Part Number800-RCS1-01
Item NameCalibration System,ventilator
FSC / FSG6545 / 65 — Replenishable Field Medical Sets, Kits, and Outfits
ManufacturerZoll Medical Corporation Dba Zoll
StatusACTIVE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
800-RCS1-01 PRIMARY Zoll Medical Corporation Dba Zoll (USA)
Reference documents
ReferenceMeaning
571-RCS1-01 5/9 Secondary reference
Impact Instrumentation Inc. Dba Impact Medical
32165 5/1 Secondary reference
U.S. Government activity
6545NCM127821 5/1 Secondary reference
Defense Medical Standardization Board

Frequently Asked Questions

What is NSN 6545-01-606-1476?

NSN 6545-01-606-1476 is a Calibration System,ventilator, manufactured by Zoll Medical Corporation Dba Zoll, classified under FSC 6545, Replenishable Field Medical Sets, Kits, and Outfits. Status: active.

What part numbers are listed for NSN 6545-01-606-1476?

NSN 6545-01-606-1476 has 1 manufacturer part number on file: 800-RCS1-01 (Zoll Medical Corporation Dba Zoll).

What are the specifications of 800-RCS1-01?

Key specifications for 800-RCS1-01: Special Features: REMOTE CALIBRATION SYSTEM; INCLUDES: (1) REMOTE CALIBRATION SYSTEM 571-RCM1-01, (1) REMOTE CALIBRATION MODULE 571-RCM1-01, (1) BACTERIA FILTER 465-0030-00, (1) USB A TO MINI B CABLE 708-0059-00, (1) O2 SENSOR CABLE 708-0060-00, (1) TRANSDUCER OXYGEN SENSOR 804-0008-00, (1) O2 SENSOR THREADED TEE 820-0128-00, (1) TEST LUNG W/ 22MM ELBOW 820-0105-00, (1) VENTILATOR CIRCUIT SINGLE LIMB WYE 820-0106-00, (1) O2 "Y" TUBING ASSEMBLY W/ QUICK DISCONNECT 703-RCM1-01, (1) TUBING ASSEMBLY FUNCTIONAL TEST Y ADAPTER 703-RCM1-02, (1) CALIBRATION RESISTOR (R NO.1) 820-0129-00, (1) OXYGEN REGULATOR ASEMBLY 703-RCM1-04, (1) YOKE ADAPTER CGA 870 X CGA 540 480-0344-00, (1) FUNCTIONAL TEST RESISTOR (R NO.2) 820-0127-00, (1) LAPTOP PC (W/POWER SUPPLY) CONFIGURED FOR IMPACT RCS USE ONLY; (1) QUICK REFERENCE GUIDE 907-RCS1-01, (1) OPERATION MANUAL 906-RCS1-01, (1) TRANSIT CASE ASSEMBLY 703-RSC1-01 MM; Part Name Assigned by Controlling Agency: CALIBRATION SYSTEM 731 VENTILATOR WITH TRANSIT CASE. 0 specifications are documented in the U.S. Government catalog.

Is NSN 6545-01-606-1476 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com