PartsTable TECHNICAL DATA SHEET
NSN 6530-01-702-2905Government record, cited

Tray, Catheter, Central Venous6530-01-702-2905

NSN 6530-01-702-2905 · NIIN 017022905 · Part number G44128
Cook Medical Llc · FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies · FSG 65 — Medical, Dental, and Veterinary Equipment · CAGE 393H0
Government record, cited
NSN 6530-01-702-2905 — this item is cataloged by the U.S. Government under National Stock Number 6530-01-702-2905. Manufacturer of record part number: G44128.
Also searched as  6530-01-702-2905 · 6530017022905 · NIIN 017022905 · 01-702-2905 · FSC 6530 Hospital Furniture, Equipment, Utensils, and Supplies · CAGE 393H0 · G44128 · 6530NCM228280 · 1633784
Nearby stock numbers  ·
Features
  • Tray,catheter,central Venous — FSC 6530
  • Cubic Measure: 0.1094 CUBIC FEET
  • 1 manufacturer part number on file
  • Manufacturer of record: Cook Medical Llc
Identification
  • NSN: 6530-01-702-2905
  • NIIN: 017022905
  • FSC: 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
  • FSG: 65 — Medical, Dental, and Veterinary Equipment
  • Primary part number: G44128
  • Manufacturer: Cook Medical Llc
General Description

The Tray,catheter,central Venous, cataloged under National Stock Number 6530-01-702-2905, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Cook Medical Llc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.

Technical Specifications
ParameterValue
NSN6530-01-702-2905
Primary Part NumberG44128
Item NameTray,catheter,central Venous
FSC / FSG6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies
ManufacturerCook Medical Llc
StatusACTIVE
Cubic Measure0.1094 CUBIC FEET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Unit of IssueEA
Cross-Reference Index
Part NumberManufacturer
G44128 PRIMARY Cook Medical Llc (USA)
Reference documents
ReferenceMeaning
6530NCM228280 5/1 Secondary reference
Defense Medical Standardization Board
1633784 5/1 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 6530 — Hospital Furniture, Equipment, Utensils, and Supplies
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
6530-00-003-5096
6530-00-003-5096 · Item name not on file
6530-00-003-5137
6530-00-003-5137 · Item name not on file
6530-00-003-5185
6530-00-003-5185 · Item name not on file
6530-00-004-4189
6530-00-004-4189 · Item name not on file
6530-00-005-3929
6530-00-005-3929 · Item name not on file
6530-00-006-3497
CHAIR,COMMODE
6530-00-006-4719
6530-00-006-4719 · Item name not on file
6530-00-006-5948
6530-00-006-5948 · Item name not on file

Frequently Asked Questions

What is NSN 6530-01-702-2905?

NSN 6530-01-702-2905 is a Tray,catheter,central Venous, manufactured by Cook Medical Llc, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.

What part numbers are listed for NSN 6530-01-702-2905?

NSN 6530-01-702-2905 has 1 manufacturer part number on file: G44128 (Cook Medical Llc).

What are the specifications of G44128?

Key specifications for G44128: Special Features: 7.0 FR POWER-INJECTABLE TRIPLE LUMEN MINOCYCLINE AND RIFAMPIN IMPREGNATED CENTRAL CATHETER. CATHETER LENGTH 20CM, WIRE GUIDE DIM 0.032. TRAY INCLUDES(1) CENTRAL VENOUS CATHETER,(1)DISPOSABLE SAFETY SCALPEL, (1) NEEDLELESS SALINE LOCK, (1) INTRODUCER NEEDLE,(1) CHLORAPREP ONE-STEP LARGE FENESTRATED DRAPE W/CLEAR WINDOW, (1) PRE-FILLED SODIUM CHLORIDE SYRINGE, (1) SHARPS NEEDLE HOLDER CUP, (1) CURVED NEEDLE WITH SUTURE AND NEEDLE HOLDER, (1) STRAIGHT AND CURVED DOUBLE FLEXIBLE TIPPED WIRE GUIDE, (1) DILATOR, (1) SYRINGE, (1) 25G NEEDLE, (1) 22G NEEDLE, (1) TFE CATHETER INTRODUCER NEEDLE G; Cubic Measure: 0.1094 CUBIC FEET; Part Name Assigned by Controlling Agency: CATH TRAY, CVC TRPLE LUMEN ANTIMIC 7FR. 1 specification is documented in the U.S. Government catalog.

Is NSN 6530-01-702-2905 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com