The Tray,catheter,central Venous, cataloged under National Stock Number 6530-01-590-7430, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Teleflex Llc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6530-01-590-7430 |
| Primary Part Number | CS-22142-CF |
| Item Name | Tray,catheter,central Venous |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Manufacturer | Teleflex Llc |
| Status | ACTIVE |
| Accessory Components and Quantity | 1-SPRING-WIRE GUIDE;1-CATHETER 16GAX 4.8CM RADIOPAQUE OVER 19GA TW INTRODUCER NEEDLE;1-PRESSURE TRANSDUCTION PROBE;1-INTRODUCER NEEDLE 18GA;2-TISSUE DILATOR;1-SUTURE WING;1-DRAPE 24X36;NO 11 SCALPEL CM |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| CS-22142-CF PRIMARY | Teleflex Llc (USA) |
| Reference | Meaning |
|---|---|
| CS-22142-CF | 3/9 Design control — primary reference Arrow International, Inc. Dba Teleflex |
NSN 6530-01-590-7430 is a Tray,catheter,central Venous, manufactured by Teleflex Llc, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
NSN 6530-01-590-7430 has 1 manufacturer part number on file: CS-22142-CF (Teleflex Llc).
Key specifications for CS-22142-CF: Accessory Components and Quantity: 1-SPRING-WIRE GUIDE;1-CATHETER 16GAX 4.8CM RADIOPAQUE OVER 19GA TW INTRODUCER NEEDLE;1-PRESSURE TRANSDUCTION PROBE;1-INTRODUCER NEEDLE 18GA;2-TISSUE DILATOR;1-SUTURE WING;1-DRAPE 24X36;NO 11 SCALPEL CM; Special Features: 1-TWO LUMEN INDWELLING CATHETER, CURVED:14FR X 15CM, RADIOPAQUE POLYURETHANE WITH BLUE FLEX TIP ARROWG+ARD ANTIMICROBIAL SURFACE TREATMENT, EXTENSION LINE CLAMPS AND INJECTION SITE CLAMPS. CM; Part Name Assigned by Controlling Agency: TWO LUMEN HEMODIALYSIS CATHETERIZATION SET, 5/CASE. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.