The Enclosure,still Air, cataloged under National Stock Number 6530-01-583-6812, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Plas-Labs Inc. Government technical data includes 1 specification, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active. Unit of issue: EA.
| Parameter | Value |
|---|---|
| NSN | 6530-01-583-6812 |
| Primary Part Number | 825-PCR/HEPA |
| Item Name | Enclosure,still Air |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Manufacturer | Plas-Labs Inc |
| Status | ACTIVE |
| Voltage in Volts and Current Type | 110.0 AC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Unit of Issue | EA |
| Part Number | Manufacturer |
|---|---|
| 825-PCR/HEPA PRIMARY | Plas-Labs Inc (USA) |
| Reference | Meaning |
|---|---|
| 16181 | 5/1 Secondary reference U.S. Government activity |
| 6530NCM104325 | 5/1 Secondary reference Defense Medical Standardization Board |
| PCR CHAMBER | 5/1 Secondary reference Plas-Labs Inc |
NSN 6530-01-583-6812 is a Enclosure,still Air, manufactured by Plas-Labs Inc, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
NSN 6530-01-583-6812 has 1 manufacturer part number on file: 825-PCR/HEPA (Plas-Labs Inc).
Key specifications for 825-PCR/HEPA: Overall Height: 28.000 INCHES NOMINAL IN; Voltage in Volts and Current Type: 110.0 AC; Overall Width: 26.000 INCHES NOMINAL IN; Special Features: STILL AIR ENCLOSURE PCR (UVC) CHAMBER; CONTAINS BOTH FLUORESCENT AND UV GERMICIDAL LAMPS; UV SYSTEM RATED AT 254 NM TO DECONTAMINATE ALL INTERIOR SURFACES; 0.5 IN THICK OPTICALLY CLEAR FRONT PANEL; EFFECTIVE AGAINST BETA RAYS, BUT NOT GAMMA RAYS; REMOVABLE DOORS; REMOVABLE DOORS AND SIDE ACCESS PANELS; PROXIMITY SENSORS TURN OFF POWER TO UV SYSTEM WHEN DOORS ARE OPENED; POWER REQUIREMENTS: 110-115 V, 60 HZ, W/ 2 AMP CIRCUIT BREAKER; OUTSIDE DIMENSIONS: 26 IN W X 23 IN D X 28 IN H; INSIDE DIM.: 23.5 IN W X 17 IN D X 21 IN H; INCLUDES HEPA FILTER V. 1 specification is documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.