The Tray,catheter,central Venous, cataloged under National Stock Number 6530-01-539-2251, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. The manufacturer of record is Edwards Lifesciences Comercio De Produtos Medico-Cirurgicos Ltda. Government technical data includes 2 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6530-01-539-2251 |
| Primary Part Number | M/CICA0146 |
| Item Name | Tray,catheter,central Venous |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Manufacturer | Edwards Lifesciences Comercio De Produtos Medico-Cirurgicos Ltda |
| Status | ACTIVE |
| Material | PLASTIC, POLYETHYLENE (PP) |
| Usage Design | 1 MULTI LUMEN INDWELLING CATHETER 7 FR X 8 INCH RADIOPAQUE POLYURETHANEWITH BLUE FLEXTIP EXTENSION LINE CLAMPS, INJECTION SITE CAPS; 1 SPRING WIRE GUIDE MARKED 0.032 INCH DIA X 23 5/8 INCH,STRAIGHT SOFT TIP ON ONE END-J TIP ON OTHER, WITH ARROW ADVANCER; 1FASTENER CATHETER CLAMP; 1 INTRODUCER NEEDLE 18 GA X 2 1/2 INCH XTW; 1 ARROW RAULERSON SPRING WIRE INTRODUCTION SYRING 5 CC; 1 PRESSURE TRANSDUCTION PROBE; 1TISSUE DILATOR; 1 CLAMP CATHETER IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| M/CICA0146 | Edwards Lifesciences Comercio De Produtos Medico-Cirurgicos Ltda (BRA) |
| TRIPLO LUMEN 20CM/7F | Edwards Lifesciences Machi Ltda. (BRA) |
| Reference | Meaning |
|---|---|
| CV-15703-E | 3/9 Design control — primary reference Arrow International, Inc. Dba Teleflex |
NSN 6530-01-539-2251 is a Tray,catheter,central Venous, manufactured by Edwards Lifesciences Comercio De Produtos Medico-Cirurgicos Ltda, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
NSN 6530-01-539-2251 has 2 manufacturer part numbers on file: M/CICA0146 (Edwards Lifesciences Comercio De Produtos Medico-Cirurgicos Ltda), TRIPLO LUMEN 20CM/7F (Edwards Lifesciences Machi Ltda.).
Key specifications for M/CICA0146: Part Name Assigned by Controlling Agency: ARROW HOWES MULTI LUMEN CENTRAL CATHETERIZATION SET WITH BLUE FLEXTIP 10/CASE; Material: PLASTIC, POLYETHYLENE (PP); Usage Design: 1 MULTI LUMEN INDWELLING CATHETER 7 FR X 8 INCH RADIOPAQUE POLYURETHANEWITH BLUE FLEXTIP EXTENSION LINE CLAMPS, INJECTION SITE CAPS; 1 SPRING WIRE GUIDE MARKED 0.032 INCH DIA X 23 5/8 INCH,STRAIGHT SOFT TIP ON ONE END-J TIP ON OTHER, WITH ARROW ADVANCER; 1FASTENER CATHETER CLAMP; 1 INTRODUCER NEEDLE 18 GA X 2 1/2 INCH XTW; 1 ARROW RAULERSON SPRING WIRE INTRODUCTION SYRING 5 CC; 1 PRESSURE TRANSDUCTION PROBE; 1TISSUE DILATOR; 1 CLAMP CATHETER IN. 2 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.