The Tray,catheter,central Venous, cataloged under National Stock Number 6530-01-539-2250, is classified within Federal Supply Class 6530 (Hospital Furniture, Equipment, Utensils, and Supplies) of the Medical, Dental, and Veterinary Equipment group. Government technical data includes 3 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 6530-01-539-2250 |
| Item Name | Tray,catheter,central Venous |
| FSC / FSG | 6530 / 65 — Hospital Furniture, Equipment, Utensils, and Supplies |
| Status | ACTIVE |
| Accessory Components and Quantity | 1 TWO LUMEN INDWELLING CATHETER 7 FR X 8 IN, RADIOPAQUE POLYURETHANE WITH BLUE FLEXTIP EXTENSION LINE CLAMPS INJECTION SITE CAPS; 1 SPRING WIRE GUIDE MARKED 0.032 INCH DIA X 23 5/8 INCH, STRAIGHT SOFT TIP ON ONE END-J TIP ON OTHER, WITH ARROW ADVANCER; 1 FASTENER CATHETER CLAMP; 1 INTRODUCER NEEDLE18 GA X 2 1/2 INCH XTW; 1 PRESSURE TRANSDUCTION PROBE; 1 ARROW RAULERSON SPRING WIRE INTRODUCTION SYRINGS 5 CC; 1 TISSUE DILATOR; 1 CLAMP CATHETER IN |
| Material | PLASTIC, POLYETHYLENE (PP) |
| Usage Design | CARDIAC ASSIST, CRITICAL CARE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| CV-17702-E | 3/9 Design control — primary reference Arrow International, Inc. Dba Teleflex |
NSN 6530-01-539-2250 is a Tray,catheter,central Venous, classified under FSC 6530, Hospital Furniture, Equipment, Utensils, and Supplies. Status: active.
Key specifications for 6530-01-539-2250: Accessory Components and Quantity: 1 TWO LUMEN INDWELLING CATHETER 7 FR X 8 IN, RADIOPAQUE POLYURETHANE WITH BLUE FLEXTIP EXTENSION LINE CLAMPS INJECTION SITE CAPS; 1 SPRING WIRE GUIDE MARKED 0.032 INCH DIA X 23 5/8 INCH, STRAIGHT SOFT TIP ON ONE END-J TIP ON OTHER, WITH ARROW ADVANCER; 1 FASTENER CATHETER CLAMP; 1 INTRODUCER NEEDLE18 GA X 2 1/2 INCH XTW; 1 PRESSURE TRANSDUCTION PROBE; 1 ARROW RAULERSON SPRING WIRE INTRODUCTION SYRINGS 5 CC; 1 TISSUE DILATOR; 1 CLAMP CATHETER IN; Part Name Assigned by Controlling Agency: TWO-LUMEN CENTRAL VENOUS CATHETER WITH BLUE FLEXTIP CATHETER 10/CASE; Material: PLASTIC, POLYETHYLENE (PP); Usage Design: CARDIAC ASSIST, CRITICAL CARE. 3 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.